My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21420
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21420
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 2:13:20 PM
Creation date
1/8/2020 2:13:18 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21420
Building Department - Name
LENNAR HOMES LLC
Address
6328 COBBLE BLISS ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 26 Date: 51212019 DSvwSR <br /> 2019 <br /> Entire House By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 28442 Btuh Entering coil DB: 75.5°F <br /> Outdoor design WB: 77.3°F Latent gain: 3445 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 31887 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29750. Btuh 105% of load <br /> Latent capacity: 5250 Btuh 152% of load <br /> Total capacity: 35000 Btuh 110% of load SHR: 85%- <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB:- 30.8°F Heat loss: 33542 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance.Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Output capacity: 26719 Btuh 80% of load Capacity balance: 32 °F <br /> Supplemental heat required: 6823 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual S. <br /> -0fil- wrightsoft- 2019-May-02 06:32:59 <br /> �� .R•�P Lbw»u-��ma; Right-Suite®Universal 2018 18.0.16 RSU05714 <br /> " Page 1 <br /> ...ipment\2606 sf ADS template VW 3ton Carrier.rup Calc=MJS Front Door faces:NW <br />
The URL can be used to link to this page
Your browser does not support the video tag.