Laserfiche WebLink
DAS <br /> Building and Construction Services(BCS) <br /> I -LA. C <br /> c <br /> Yt� rrr <br /> COUNTY FLORIDA Blower Door Test Report Form <br /> OPEN SPACES. PLACES. <br /> Property Address: Unit M <br /> ermit I T om y N e: <br /> Test Date: Test r Na e: <br /> w b—113 <br /> Tester C #: conta PJ�o <br /> Em o <br /> 0 <br /> 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).As required by <br /> the Building Official,testing shall be conducted by an approved third party.A written report of the results of the test <br /> shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior <br /> to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled <br /> penetrations of the building thermal envelope. <br /> During testing:(check to verify condition met) <br /> ❑ Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br /> weather-stripping or other <br /> ❑Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond <br /> intended infiltration <br /> ❑Interior doors,if installed at the time of the test,shall be open <br /> ❑Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed <br /> ❑Heating and cooling systems,if installed at the time of the test,shall be turned off <br /> ❑Supply and return registers,if installed at the time of the test,shall be fully open <br /> Vb Building volume(ft) _ -�a -J q I , <br /> Qso Airflow at 50 Pascal(CFM) <br /> ACHso Air changes per hour at 50 Pascal <br /> Qso x 60_Vb = _ ACH5o (3.0 ACH minimum) <br /> Pass ] Fail ❑ <br /> ❑Outside Air mechanically introduced to space(less than 3.0 ACH) <br /> I hereby certify that the above envelope leakage performance results demonstrate compliance <br /> with Florida E gy Code requirements in accordance with Section R402.4.1.2. <br /> &VAre of Tester Data <br />