My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21425
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21425
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 2:17:09 PM
Creation date
1/8/2020 2:17:08 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21425
Building Department - Name
LENNAR HOMES LLC
Address
6356 COBBLE BLISS ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building and Construction Services(BCS) <br /> PAINU * <br /> Y ` <br /> COUNTY FLORIDA Blower Door Test Report Form <br /> OPEN SPACES. I'ILM- -1-PL;kC;ES. � <br /> Property Address: Unit <br /> Permit i# Testi� m n ame: <br /> Test ate: Test Na <br /> Tester Ge #: Contact one: n <br /> E aih �l <br /> w <br /> 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).As required by <br /> the Building Official,testing shall be conducted by an approved third party.A written report of the results of the test <br /> shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior <br /> to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled <br /> penetrations of the building thermal envelope. <br /> During testing.(check to verify condition met) <br /> ❑ Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br /> weather-stripping or other <br /> ❑Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond <br /> intended infiltration <br /> ❑Interior doors,if Installed at the time of the test,shall be open <br /> ❑Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed <br /> ❑Heating and cooling systems,if installed at the time of the test,shall be turned off <br /> ❑Supply and return registers,if installed at the time of the test,shall be fully open <br /> Vb Building volume(ft') <br /> Qso Airflow at 50 Pascal(CFM) <br /> ACHso Air changes per hour at 50 Pascal <br /> Qso x 60 Vb = i } ACH5o (10 ACH minimum) <br /> Pass MA Fail ❑ <br /> ❑Outside Air mechanically introduced to space(less than 3.0 ACH) <br /> I hereby certify that the above envelope leakage performance results demonstrate compliance <br /> with Florida Energy Code requirements in accordance with Section R402.4.I.2. <br /> Signa Tester —'Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.