My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21488
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21488
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 2:38:55 PM
Creation date
1/8/2020 2:38:54 PM
Metadata
Fields
Template:
Building Department
Company Name
ALPHA VILLAGE
Building Department - Doc Type
Permit
Permit #
19-21488
Building Department - Name
DINNING,LARRY & LORI
Address
7345 APPLEGATE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'\J <br /> TRINIIY J ERD <br /> 4.3 Accessory Starter Strips: <br /> 4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlocker'"I Premium Eave/Rake Starter Strip Shingles <br /> are starter strips for asphalt roof shingles. <br /> 4.3.2 QuickStart° Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS <br /> modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6- <br /> inch or less. <br /> 4.3.3 StarterMatch'"I Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and <br /> Grand Sequoia® series asphalt shingles. StarterMatch"I are installed as the second starter for Grand <br /> Canyon®and Grand Sequoia®series installations. <br /> 5. LIMITATIONS: <br /> 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the <br /> Designer of Record for any project on which this Evaluation Report, or previous versions thereof;•;is/was <br /> used for permitting or design guidance unless retained specifically for that purpose. <br /> 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. <br /> 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials <br /> Directory for fire ratings of this product. <br /> 5.4 Wind Classification: <br /> 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and <br /> R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for <br /> use in all wind zones up to Vasd=150 mph(V,,It=194 mph). Refer to Section 6 for installation requirements <br /> to meet this wind rating. <br /> 5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 <br /> and R905.2.6.1 to ASTM.D3161, Class F, indicating the shingles are acceptable for use in all wind zones up <br /> to Vasd=150 mph(V,,it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. <br /> 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3,and a <br /> mean roof height of 60 feet or less. Calculations by a qualified design professional are required for <br /> conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. <br /> 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. <br /> 6. INSTALLATION: <br /> 6.1 Underlayment: <br /> 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be <br /> Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. <br /> 6.2 Starter Shingles or Starter Strip: <br /> 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip <br /> Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. <br /> 6.3 Asphalt Shingles: <br /> 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four <br /> (4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: <br /> ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, <br /> and Woodland require minimum five(5) nails per shingle. <br /> ➢ Slateline requires minimum six(6)nails per shingle. <br /> 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 <br /> or R905.2.5. Staples are not permitted. <br /> 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are <br /> required. Contact the GAF for details. <br /> Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122 <br /> Certificate of Authorization#9503 6TN EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20 <br /> GAF Asphalt Roof Shingles Revision 22:09/20/2017 <br /> Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.