Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1. .F.F..E. shall be a minimum of.8" above the road elevation and an engineered.site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. _Compaction test required if 24" or more:of fill dirt is.brought_in at any one place: . <br /> 4. -Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W.use permit. All 4 sides of.driveway thru the sidewalk shall have = . <br /> expansion maternal: <br /> 6. All, setbacks.shall.be met. . <br /> T. All.property:markers shall be uncovered and marked at time of first 'inspection: <br /> 8. :All A.D.A. requirements shall be met.:'. <br /> 9. No electric,plumbing,mechanical, or(raining shall be:covered without an inspection arid <br /> approval first. . . <br /> 10. All Garages shall comply,with section R3016 of the.F.B.C..(Fire Separation).. <br /> 11. Appliances:shall not:be installed in a location where subjectto mechanical damage unless <br /> proto6ted.bv approved barriers. M303.4 of the F.B:C. <br /> 12. Water heaters'shall comply.with section P607.3 of the F.R.C. <br /> 11 Foundation supports for A/C.units shall be raised at least 3"-above finished grade,. M1308.1. <br /> 14. Return air in all.bedrooms..F.B.C. Ml620A <br /> 15: Smoke detectors:are.to be'installed in accordarnce-with:R313' of the.F.B.C. <br /> 16:.All glazing requirements are.to be in accordance-with-R308.4,of the F.B.-C. . <br /> 17. All means of egress are to be in accordance with R31.1 the RB.C. :. <br /> 18. "Green gypsum'.board shall riot be used as.a backer in:showers or.tubs.R702.44.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required;at all locations requiring an AFCI type breaker: <br /> 20. Carbon monoxide.alarms.will be required in new construction that uses fossil-burning heating <br /> or appliances or ani attached garage. They shall be installed'in accordance with.the F.B.C. . <br /> 21. All plumbing,mechanical, and:electnc l shall:be separate from unit to:unit: This includes all. <br /> underground plumbing and electric. <br /> 22. All 2011 N:E.C: Codes:will be enforced: <br /> - <br /> 23. Tamper= Resistant Receptacles in accordance with 406.11 of the 2011 N.E:C <br /> 24: In accordance:with the Land Development Code lots shall be sodded before final at least 10. <br /> feet around the structure: <br /> 25.A.copy of the energy caels shall be with permitat all times. : . <br /> 26 _Copy of final insulation reportshall be.provided with-permit-before. haL - <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6'Edition- <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code (2011) <br />