Laserfiche WebLink
Single Family Dwelling <br /> Plan Review:CO mments: <br /> 1:" F.F.E. shall be a minimum of.8 above.the road elevation and"an engineered site plan. . . <br /> 2_ Lots shall be graded.to comply with.R401.3 of the F.B.C. <br /> 3.- .Compaction lest required if 24" or more of fill dirt is brought in:at any one place. : <br /> 4:. 'Tie in survey-required before pouring concrete.. <br /> 5. _Driveways require a R.O.W.use permit: All 4.sides of driveway.thru the sidewalk shall-have. " <br /> expansion material:. . . <br /> 6.." All setbacks.'shall be'met: <br /> 7. :Ali.property markers�shall be_uncovered and'marked at time of first:inspection: <br /> 8." :All A.D.A.requirements shall be met. <br /> 9. No:electric;plumbing,mechanical;"or framing shall be covered without an:inspection and <br /> approval"first. <br /> 10. All Garages shall comply,with section R302:6 of the F.B:C: (F.i.re Sp.aration. <br /> � <br /> 11.:Appliaiices.shall iiot.be installed in a location where subject to."mechanical"damage:unless. <br /> protected by approved barriers. M303.4 of."the F.B.C. " <br /> 12. Water heaters shall comply:with section:P607.3 of the"F.B.C: <br /> 13. Foundation supports for-A/C units shall be raised at least 3"above finish ed"grade. M1308.1 <br /> 14. Return air in All-.bedrooms..F.B.C. NI1620.4,, <br /> 15. Smoke detectors are to be'installed:"in accordance.with R313:1-oftheT.B.C. <br /> .16::All glazing requirements are:.to be'in accordance with R308.4.of the RB:C. <br /> 17. All means,of egress"are to be in accordance with R311:.of the F.B.C., <br /> 18. `.`Green gypsurn.board shall not be used:as"a"backer in:showers or tubs."R702.4.2.F.B.C. <br /> 19. Combination-type"AFCI breakers are required:at all.locations-requiring an AFCI.type breaker. <br /> 20: Carbon'monoxide alarms will be required in.-new.construction thzat uses fossil-burning heating <br /> or appliances or an attached garage_: They shall be installed in accordance with"the F.B.C:: <br /> 21. All plumbing,mechanical,:and electrical shall:be separate from unit to:unit. This includes all, <br /> underground plumbing and electric. <br /> 22.--A11,2016:N.E C.. Codes.will.be enforced. <br /> .. <br /> 23:-Tamper- Resistant Receptacles in accordance with 406.11 of the 20"16 N".E:C <br /> .24.:In, accordance:.with the Land.Development:Code,lots shall be sodded before final at least 10. ." <br /> feet around:the structure. : . <br /> 25. Blower"door test and blown in insulation card shall be"provided before C..O . :" <br /> 26 A copy®fthe enemy cacls.shall be with permit"at all times. <br /> 2T. Copy of final insulation report shall be:provided with.permit-before fnab . <br /> F.F.E.-Finished Floor Elevation <br /> RB.C=Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D:A:-Americans with Disabilities Act" N.E.C.-National Electric Code(2011) <br />