Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA EN.ERGY._EFFICIENCY CODE FOR BUILDING',CONSTRUCTION <br /> Florida Department of Business and Professional Regulation- Residential Performance Method <br /> Project Name: R0818445 Builder;Name: Pete Richter Construction Inc <br /> Street: 40134 Chancey Rd' ' ' Permit Office: City of Zephyrhills <br /> City,State;Zip: Zephyrhills,FL 33540 Permit Number. ZO-2,7_ <br /> Owner. Jamie Crews Jurisdiction:•., 611600 <br /> Design•Location: FL,.Tampa Intl AP,: County: (Florida Climate Zone 1) <br /> 1.New construction or existing New(From Plans) 9. Wall types(3803 ft� Insulation(R) Area(" <br /> 2.Single family or multiple family Single Family a. Blk wall,stucco ext,.r-4.1.ext bd 4.1 1696.67 <br /> b. Frm wall,adjacent 13.0 226.09 <br /> 3.Number of units,if•multiple family 1 c. Frm wall,foam. 14.0--. 1190.00 <br /> 4.Number of bedrooms 2 d. Knee wall,mti roof mat,r-20 to 39.0 690.00 <br /> 10. 'Ceiling types"(1754 fP) Insulation(R) Area(ft� <br /> 5.is this a worst case? No a.Attic ceiling,nit]roof mat,r-20 20.0 ` 226.44 <br /> 6.Conditioned loot area above grade(ftJ 2704.00 . ' b.Attic ceiling,mtl roof mat,r-20 20.0 1527.11 <br /> Conditioned floor area below grade(81 0 :_. c. N/A . <br /> 7. Windows 384 it) Description Area 11.Ducts R Area(ft� <br /> ( ) p 7 a.AHU1 6.0 175.00 <br /> a.U-Factor: Dbl-Low-e,0.350 383.67 <br /> SHGC: 0.30 b.AHU2 Attic 6.0 125.00 <br /> , <br /> b.U=Factor. 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Split air source heat pump 34.2 SEER:16.0 <br /> c.U-Factor b.Split-air source heat pump 17.8- SEER:16.0 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d.U-Factor: a.Split air source heat pump 35.0 HSPF:9.0 <br /> SHGC: b.Split air source.heat pump .; 18.0 HSPF:9.0 <br /> Area Weighted Average Overhang Depth: 6.293 ft 14.Hot water systems <br /> Area Weighted Average SHGC: 0.300 a.Electric conventional(50,gal) Cap:50 gal <br /> EF:0.97 <br /> 8..Floor types(1753.56 ft') Insulation(R) Area(ft2) b.Conservation features <br /> a. Floor,Slab on Grade 0.0 1644.00 (None) <br /> 15.Credits Ceiling Fan <br /> Glass/FI'oor area:.0.142 Total Proposed Modified Loads: 107.06. PASS <br /> Total Baseline.Loads: " 109.23 <br /> I hereby certify that the plans and specifications covered by , Review of the plans and specifications Tt1E S7• <br /> this calculation are in compliance with the Florida Energy covered by this calculation indicates 0ti <br /> Code. compliance with the Florida Energy' <br /> Code.Before constriction is.completed, <br /> this building will be inspected for:., <br /> PREPARED BY: � 9 p �, ,, .•,�„�.�_ „ <br /> Compliance with Section 553.908 r i <br /> DATE: 09-05-18 Florida Statutes. <br /> w Lo'I hereby certify that this building,as designed;is in <br /> compliance with the Flo' eVy e._OWNER/AGENT BUILDING OFFICIAL:- <br /> DATE: q l :,le _ . DATE: . <br /> -Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project <br /> .requires an envelope leakage test report with envelope leakage no greater.than,7.0 ACH50.(R402.4.1.2). <br /> 2018Sep-05 21:39:14 <br /> wrightsoW Rght-Suite®thiversal 201818.027 RSU07440 Right-Energy®Florida 2017 :Section 405.4.1 Compliant Software page 2 <br /> iw:a•:r .,_��c .• ...oft HVAC1Template\Pete Richter Construction.rLd Colo=MJ8 Front Door faces: N <br />