Laserfiche WebLink
SOm AED Assessment Date: 11/25/2019 <br /> RUUD Entire House By: <br /> Project Information <br /> For: <br /> 39337 5th Avenue,Zephyrhills, FL 33542 <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Hernando Co,FL, US Indoor temperature(T) 70 75 <br /> Elevation: 79 ft Design TD(T) 36 16 <br /> Latitude: 28°N Relative humidity(%) 30 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 10.1 49.3 <br /> Dry bulb(°F) 34 91 Infiltration: <br /> Dailyrange(T) - 17 ( M ) <br /> Wet bu I b(°F) - 76 <br /> Wind speed(mph) 15.0 7.5 <br /> Test for • - • Exposure Diversity <br /> Hourly Glazing Load <br /> 710OCT <br /> 6,00 . <br /> 5,00 <br /> 4,00 <br /> 3,00 <br /> 2,00 <br /> 1,00 <br /> 08 9 10 11 12 13 14 15 16 17 18 19 20 <br /> Hour of Day <br /> O Hxdy / Average / PED limit <br /> Maximum hourly glazing load exceeds average by 19.4%. <br /> House has adequate exposure diversity (AED), based on AED limit of 30%. <br /> AED excursion: 0 Btuh <br /> 2019-Nov-2514:50:04 <br /> ;.t Right-Suite®Universal 2019 19.0.08 Right JO Mobile Page 1 <br /> \wstmp\3ce6d5aa-701f-47da-8bOa-135de3f40aa1.rup Calc=MJ8 Front Door faces: N <br />