Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R40.1.3 of the F.B.C. <br /> 3. Compaction_test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material-. <br /> 6. All setbacks shall be.met: <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric, plumbing,mechanical, or framing shall be covered without an:inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> I I._Appliances shall not be installed in a location where subject to mechanical damage unless <br /> .protected by approved barriers. M303.4 of the F.B:C <br /> 12. Water.heaters shall comply with section P607.3 of thee.F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in,all bedrooms. F.B.C. M,1620.4 <br /> 15. Smoke detectors are to be 'installed in accordance with R313.1 of the F.B.C. <br /> 16, All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in.accordance with R311 of the F.B.C. <br /> 18. "Green gypsum N ard" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCTbreakers are required at all.locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil.-burning heating <br /> or appliances or an attached garage: They shall be installed'in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to:unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2616 N.E.C. Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406:11 of the 2016 N:E:G <br /> 24: In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: Blower door test and blown in insulation card shall be provided before C.O. <br /> 26. A copy of the energy cacls shall be with permit at all times. <br /> 2 Z Copy of final insulation report shall be:provided with:pertnit before.ftnaL <br /> 28:No fence,:pool or screen enclosure is.issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-:Florida Building Code 6th Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />