Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be:graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any,one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk.shall have <br /> expansion material. <br /> 6. All setbacks shall be met: <br /> 7. All.property markers shall be uncovered and marked at time of first inspection. <br /> 8. All Ab.A:requiremeiits shall be met. <br /> 9: No electric, plumbing, mechanical; or framing shall be covered without an.inspection and <br /> approval first. <br /> 10. All. Garages.shall comply with,section R302.6 of the F.B.C..(Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved,barriers. M303.4.of the F.B:C <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 11 Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms: F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308A of the F,B.C. <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board'-'-shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring-an AFCI type breaker: <br /> 20. Carbon:monoxide alarms:will be required in-new construction that uses fossil-burning heating. <br /> or appliances'or an attached garage; They shall be installed in accordance with the F.B:C. <br /> 21. All plumbing, mechanical, and;electrical shall be separate from unit to:unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C-. Codes willbe enforced. <br /> 21 Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N:E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10: <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26. A copy of the energy cacls shall be with hermit at all times <br /> 27. Copy of rnal insulation report shall be fip oWded with:oerfnit before.fnaL <br /> 28:No fence,:pool or screen enclosure is.issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />