Laserfiche WebLink
R W R W Building Consultants, Inc. <br /> B Consulting and Engineering Services for the Building,Industry <br /> P.O.Box 230 Valrico.FL 33595 Phone 811659.9197 <br /> C <br /> Florida Board of Professional Engineers Certificate orAtithori7ation No.9813 <br /> ProductEvalitation J?eport Rel)ort No.: EL-15378.2 i <br /> Date: October 12, 2017 <br /> Product Sub Category Manufacturer Product Name <br /> Category <br /> NewSouth Window Solutions DuraGard <br /> Windows Double Hung 4901 Oak Fair Blvd Double Hung Window <br /> Tampa,FL 33610 <br /> (813)626-6000 "Non-Impact" <br /> Scope; Product Evaluation report issued by R W,Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> NewSouth Window Solutions,based on Rule Chapter No.61G2043,Method 1D of the State of Florida Product Approval, <br /> Dept.of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor Will acquire financial interest in the company <br /> manufacturing or distributing.the product or in any other entity involved in thee-approvall process of the product named <br /> herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements <br /> excluding the"High Velocity-Hurricane Zone'(HVHZ). <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment4b base materialshall be beyond wall dressing <br /> or stucco. <br /> 3. When used in areas requiring wind bome deltift protection,this productis requilred,to,be protected with an impact resistant covering <br /> that complies with FBC Sections,1609.1.2&R301.2.1.2. <br /> 4. Site conditions that deviate from the details of drawing.FL-15378.2 require further,engineering.analysis by a licensed engineer or <br /> registered architect. <br /> 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for.2x buck masonry construction. <br /> 6. See drawing FL-15378.2 for size'and design pressure limitations. <br /> Supporting Documents. <br /> 1. Test Report No. Test Standard Testing Laboratory ligned by. <br /> ATI A5089.03-501-44 AAMAfWDMA1bSA 101/1.8.2/A440-08 Architectu r6l Testingi Inc. Lynn George <br /> 2. Drawing No. Prepared by Sianed&Sealed b <br /> No.FL,15378.2 kW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 3. Calculations Prepared by <br /> t1latI11111%, Signed&Sealed by <br /> Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> r,E IV <br /> 4. Quality Assurance J$� %- <br /> Certificate of Participation issued by National-Accreditation and Vo, 43409 <br /> Management Institute,certifying that NewSouth Window.Solutions is <br /> manufacturing products within a quality assurance.program that,complies <br /> with ISOAEC 17020 and Guide 53. !:':A STATE OF <br /> OR , <br /> J <br /> Lyndon F.Schmidt,P.E. <br /> .. ...... ... FL PE No.43409 <br /> 1011212017 <br /> Sheet 1 of 1 <br />