My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20650
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20650
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 2:15:32 PM
Creation date
1/13/2020 2:15:31 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-20650
Building Department - Name
DR HORTON INC
Address
6813 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 6, BLOCK 12, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A & 11B <br /> NOT YET RECORDED IN PLAT BOOK ----, PAGE(S) ----, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> / <br /> GF / <br /> P / <br /> ti� 1o6.s <br /> e bhp�bc 103.6�RF� rR eC 40" <br /> /� \�Ssj;FNee4J pc,� � <br /> 0 <br /> p Z <br /> F � <br /> ? 1.1 PT <br /> \ 3F GRAPHIC SCALE002, <br /> //J\ <br /> / o \ CO \ 0 15 30 <br /> OHO <br /> -51 <br /> cp <br /> `�S d'1. bra' ?4• V•t~ <br /> 20S,53 'L X <br /> ON LOT CALCULATIONS <br /> LOT = 9,085 SQ. FT. <br /> p Q� LIVING AREA = 1,104 SQ. FT. <br /> GARAGE = 437 SQ. FT. <br /> ENTRY = 111 SQ. FT. <br /> LANAI = 0 SQ. FT. <br /> PATIO = 80 SQ. FT. <br /> \ DRIVEWAY = 380 SQ. FT. <br /> A/C PAD = 12 SQ. FT. <br /> WALKWAY = 29 SQ. FT. <br /> O3/ IMPERVIOUS = 24% <br /> = 2153 SQ. FT. <br /> / SOD = 6,932 SQ. FT. <br /> PRC/\ OFF LOT CALCULATIONS <br /> PREPARED FOR: / RIGHT of WAY = 2010 SO. FT. <br /> l� ��yy��y� Curve Table DRIVE APRON = 237 SQ. FT. <br /> D•R•HORII�I�'I Curve Length Radius Delta Chord Bearing Chord PUBLIC S/W = 542 SQ. FT. <br /> N,„ SOD = 1,231 SQ. FT. <br /> C7 106.90' 200.00' 3D37'30' S47'40'52'W 105.63' TOTALS <br /> C2 239.23' 230.00' 59'35'41' N46'08'45'E 228.59' AREA = 11.095 SQ. FT. <br /> DRIVEWAY = 617 SQ. FT. <br /> BUILDING SETBACKS C3 51.12' 230.00' 12'44'06' N69'3433'E 51.02' SIDEWALK = 571 SQ. FT. <br /> FRONT: 20' C4 188.11' 230.00' 46'51'35` N39'46'42-E 182.91' SOD = 8,163 SO. FT. <br /> REAR: 15' <br /> SIDE: 5' (50' LOTS) <br /> 7.5' (55' & 60' WIDTH LOTS) <br /> SIDE STREET: 15' LEGEND: <br /> NOTES: — ' — ' — BUILDING SETBACK LINE PI POINT OF INTERSECTION. <br /> PC POINT OF CURVATURE <br /> 1. ELEVATIONS SHOWN ARE PER LOT GRADING — — — CENTERLINE PT PONT OF TANGENCY <br /> PLANS PROVIDED BY THE CLIENT. — — RIGHT OF WAY LINE RP RADIUS POINT <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 XX.XX PROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE <br /> PCC POINT OF COMPOUND CURVATURE <br /> DATUM. TYP TYPICAL <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES 0 CONCRETE (P) PER PLAT <br /> CALCULATED <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C PB PLAT BOOK <br /> THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PGS PAGES <br /> OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO. FT. SQUARE FEET <br /> LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM <br /> D&UE DRAINAGE&UTILITY EASEMENT <br /> PDE PRIVATE DREASEMENT <br /> THIS IS A PLOT PLAN ONLY PUE PUBLIC UTILITYAGE EASEMENT <br /> FLOOD NOTE: SURVEYOR NOTES: <br /> I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> DATED SEPTEMBER 26. 2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> APPEARS TO UE IN ZONE 'X-, AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH <br /> 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE <br /> LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: <br /> BEARINGS SHOWN HEREON ARE BASED ON THE NORTHEASTERLY UNE A5nA 3. NOT VALID WITHOUT THE AUTHENTIC <br /> OF LOT 6, BLOCK 12 BEING S57'37'53'E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> NA ER I <br /> ELECTRONIC SEAL OF A FLORIDA LICENSED <br /> CAN <br /> (FIELD DATE:) REVISED: SURVEYOR AND MAPPER. <br /> U FR V E Y I N G °o ' Dlgimlly signed by.l...W <br /> SCALE: 1'= 30 FEET d�;:1^"r a :,•Boleman <br /> 8cM A P P I N G INC. °'` '` },DN:cn=James W Boleman, <br /> APPROVED BY: JB 3 f_ r-+ aauAnreriran Surveying&Mapping, <br /> CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 ^•� `' ,._emaiGj6oieman@asmcorpoate.co <br /> 180820 LOT 6, 3191 MAGUIRE BOULEVARD, SUITE 200 FOR <br /> '°°:"'��''� <br /> JOB No. BLOCK 12 ORLANDO, FLORIDA 32803 6ron...imc.:. m,c=US THE <br /> Date:2018.0922013256-04'00' FIRM <br /> (407) 426-7979 <br /> DRAWN BY: DSB PLOT PLAN 09 20 2018 JL WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.