My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20675
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20675
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:28:06 AM
Creation date
1/14/2020 6:50:07 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-20675
Building Department - Name
GOODELL,RENEE JUDITH
Address
5632 5TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Wind Uplift <br /> Simplified Procedure for Componenets and Cladding <br /> ASCE 7-10,Section 30.5 <br /> V= 145 mph Basic Wind Speed <br /> Exposure D ASCE 7-10,Section 26.7 <br /> A = 1.47 Adjustment Factor for building height,ASCE 7-10,Figure 30.5-1 <br /> K,= 1 Topographic Factor,ASCE 7-10,Section 26.8.2 <br /> Roof 0= 15.7 deg <br /> sanchor= 48 in Horizontal spacing of roof anchors <br /> At,;b= 12.80 sf Panel Area tributary to each roof anchor <br /> Pnet30 Net Wind Design Pressure,ASCE 7-10,Figure 30.5-1 <br /> Roof Zone Zone 1 Zone 2 Zone 3 As shown in ASCE 7-10,Figure 30.5-1 <br /> 31.5 psf 49.1 psf 89.3 psf <br /> Pnet=AKvPne,60= Design Wind Uplift Pressure,ASCE 7-10,Equation 30.5-1 <br /> Zone 1 Zone 2 Zone 3 <br /> 46 psf 72 psf 131 psf <br /> Pnet= 16 psf Minimum Design Wind Pressure,ASCE 7-10,Section 30.2.2 <br /> Use 46 psf Use 72 psf Use 131 psf <br /> Connection to Existing Roof Framing <br /> F.S.= 1 Additional Factor of Safety applied to withdrawal force,if desired <br /> Amb= 12.80 ft< <br /> DLpa1el= 2.59 psf <br /> Zone 1 Zone 2 Zone 3 <br /> WnPhe= 46 psf 72 psf 131 psf <br /> Peas=F.S.x A,rib x(0.6D-0.6W) Withdrawal force for each roof anchor <br /> Zone 1 Zone 2 Zone 3 <br /> -335.21bs -267.21bs -246.9lbs <br /> Connection Capacity <br /> db= 5/16 in Lag Screw diameter <br /> Dpen= 2.50 in Lag Screw penetration into existing framing member <br /> Southern Pine Species of wood framing <br /> Co= 1.6 Load Duration Factor for Wind Loading,NDS Table 2.3.2 <br /> Ct= 0.7 Temperature Factor,NDS Table 10.3.4 <br /> W= 235 lb/in Withdrawal Capacity NDS Equation 12.2-1 <br /> W'=Co x C,x W= 263 lb/in Adjusted withdrawal value <br /> Panow=Dpen x W,= 657 Ibs Based on penetration depth <br /> Zone 1 Zone 2 Zone 3 <br /> DEMAND= 335 lbs 267 lbs 247 lbs <br /> Max Load=0.510 OK <br /> CAPACITY= 657 lbs 6571bs 657 Ibs <br /> Page 3 of 3 'vi t® <br />
The URL can be used to link to this page
Your browser does not support the video tag.