My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20681
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20681
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:28:46 AM
Creation date
1/14/2020 6:54:35 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-20681
Building Department - Name
SWANK,MARLENE JOYCE
Address
37811 14TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Snow Load 31-40 psf <br /> Wind Speed Exposure 2:12 4 Roof Pitch c 6.12 1 7:12•c Raof Pitch c i2.12 <br /> ASCE 7-05 IASCE 7-10 irate o Zone 1 Zone 2 t Zone:3 Zone-1 Zone 2 Zone 3 <br /> H 59 <br /> 85 mph, 110 mph C 67 42 <br /> D 56 35 <br /> B 54 <br /> 90 mph 115 mph C 61 38 <br /> D 51 32 <br /> B. . . 45 <br /> 100 mph 125 mph' C 51 32 <br /> D 74 43 27 <br /> B 57 36 <br /> 110 mph 140 mph C 70 41 28 <br /> D 59 34 22 46 46 <br /> H 50 31 <br /> 120 mph 160 mph C 61 ,36 22 47 47 <br /> D 51 30 19 4.9: 40_ 40. <br /> Notes: <br /> Spacing Governed by snore toad <br /> 1.)Values'ln above table represent the maximum allowable spacing in inches for pullout forces only on Ecofastsn Solar standoff, <br /> however the designer must round down to meet appropriate rafter spacing <br /> 2.)Maximum allowed spacing approved by EcoFasion Solar is 72" <br /> 3.)Maximum allowed standoff capolty=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 8.)Bawd on Risk Category 11(ASCE 7.10)structures-less than 30 fast In height <br /> 7.)Ail adjustment factors are set to 1.No site specific engineering is included In this table <br /> Snow Load 31-40 psf <br /> Wind Speed Exposure 2:12.<Roof Pitch<6:12 1 7:12<Roof Pitch<:12:12 <br /> AS CE 7-0S ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 2oite 3 <br /> B 49 30 <br /> 90 mph. 115 mph C 35 22 <br /> D 29, 18 <br /> B 33 20 <br /> 110 mph 140 mph C 40 23 14 <br /> D 34 19 12 26- 25 <br /> Notes: <br /> -Spacing Governed by Snow toad <br /> 1.}Values in above table represent the maximum allowable spacing to Inches for pullout fortes only on EooFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcoFastan Solar Is 4W <br /> 3.)Maximum allowed standoff capclty,=547#.(per testing results) <br /> 4.)Includes additional factor of safety of.1.5 for fag pullout capacity <br /> 5.)Values based on a maxiinum'module length of 700 <br /> 6.)Based on Risk Category.II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factor are set to 1:No site speciflo engineering Is Included In this table <br /> www.ecofastensolarcom info@ecofastensolarcom 877-859-3947 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.