My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20681
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20681
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:28:46 AM
Creation date
1/14/2020 6:54:35 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-20681
Building Department - Name
SWANK,MARLENE JOYCE
Address
37811 14TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Snow load 51-60 psf <br /> -Wind Speed Exposure 2:12 a Roof Pitch<6:12 1 7.12 a Roof Pitch <br /> ASCE 7-05 ASCE:7-10 Cate o Zane 1 Zone 2 Zone 3 Zone 1 Zone 2 2one 3 <br /> 85 mph 110'mph, C 42 <br /> D. 35 <br /> B 54 <br /> 90 mph 115 mph C 38 <br /> D 51 32. <br /> B 45.. <br /> 100 mph 125 mph . C, 51 32 <br /> D 43 ' <br /> B 36 <br /> 110 mph 140 mph C 41 26 <br /> D 34 22 <br /> B 50 31 <br /> 120 mph 150 mph; C _ 36 22 <br /> 30. 19, <br /> Notes: <br /> Spacing.Governed by Snore Load <br /> 1.)Values In above table represent the maximum allowable spacing In Inches for pullout forces only on EcaFasten Solar standoff, <br /> however the designer must round down'to most appropriate rafter spacing <br /> 2.)Maximum alkwved spacing approved by EcoFasten Solar is 72" <br /> 3.)Maximum allowed standoff.capcity=547#(per testing results) <br /> 4.)includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40' <br /> 6.)Based on Risk Category ll(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering Is Included In this table <br /> Snow Load 51-60 psf <br /> wInd:S eee Exposure 2:12 a Roof Pitch K 6:12 7:12,c Roof flitch<12:12 <br /> ASCE 7-0fs ASCE 7-10, ate go Zone 1 Zone 2 Zone 3 Zone 1 Zone.2 . Zone 3 <br /> B 30 <br /> 90 mph 115 mph C 22 <br /> D 29 1$ <br /> B 20 <br /> 110 mph 140 mph C 23 14 <br /> D 19 12 <br /> 1 <br /> Notes:. <br /> Spacing Governed by Snow Load <br /> 1.)Values In above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar Is 48" <br /> 3.)Maximum allowed standoff capnity=547#(per testing results) <br /> 4.)includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a mardmum module length of 70" <br /> 6.)Based on Risk Category.il(ASCE 7.40)structures less than 30 feet in freight <br /> 7.)All adjustment factors are set to 1.No eite specific engineering is Included In this table <br /> www.ecofastensolar.com info@ecofasteftsolaccom 877-859-3947 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.