Laserfiche WebLink
Florida Building Code Online Page 2 of 3 <br /> Summary of Products <br /> FL# Model,Number or Name Description <br /> 4904.1 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S and O/S Single Door <br /> Units <br /> in»ts-of-tlse Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.0l.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure: +76.0/-76.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 R8 II FL0128.1)df <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 R8 AE 514010A.odf <br /> 3'-0"x 6'-8"max nominal size.When large missile impact Created by Independent Third Party: Yes <br /> resistance is required,hurricane protective system is NOT <br /> required.See DWG-MA-FLO128-05 for details. <br /> 4904.2 [Units <br /> od-edge Steel Side-Hinged Door 8'-0"Opaque I/S and O/S Single Door <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.02.1)df <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+70.0/-70.0 Installation Instructions <br /> Other:Evaluated for use In locations adhering to the FL4904 R8 II FL0129.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 R8 AE 514009A.odf <br /> 3'-0"x 8'-0"max nominal size.When large missile impact Created by Independent Third Party:Yes <br /> resistance is required,hurricane protective system is NOT <br /> required.See DWG-MA-FLO129-05 for details. <br /> 4904.3 Wood-edge Steel Side-Hinged Door 6'-B"Opaque I/S and O/S Door w/or w/o Sidelites <br /> Units <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC N1006110.01 odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+55.0/-55.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 R8 11 FL0128.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party; <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 R8 AE 514008A.odf <br /> 12'-0"x 6'-8"max nominal size.When large missile impact Created by Independent Third Party:Yes <br /> resistance is required,hurricane protective system is NOT <br /> required on opaque panels,but is required on glazed panels. <br /> See DWG-MA-FL0128-05. <br /> 4904.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Door w/or w/o Sidelites <br /> Units <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.02.13df <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+45.0/-50.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 R8 II FL0129.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 R8 AE 514007A.odf <br /> 12'-0"x 8'-0"max nominal size.When large missile impact Created by Independent Third Party:Yes <br /> resistance is required,hurricane protective system is NOT <br /> required on opaque panels,but Is required on glazed panels. <br /> See DWG-MA-FL0129-05. <br /> 4904.5 Wood-edge Steel Side-Hinged Door 8'-0"Opaque O/S w/or w/o Sidelites <br /> Units <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC N1006110 02 odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure: +50.0/-45.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 R8 II FL0129.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> _3�T ______�l !"�TTT�7/"1__.�.T_.i_T__T___TT'ATT_T_7[1_'nnz/ 1. 1 in/r n1 n <br />