Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction:test required if.24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5: Driveways require a R.O.W. use permit. All sides of driveway thru the sidewalk shall Have <br /> expansion material. <br /> 6. All setbacks shall be met.. <br /> 7. All property:,markers shall be uncovered and marked at time of first.inspection. <br /> 8. All A.D.A.requirements shall be met. <br /> 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11..Appliances shall not be installed in a location where subject to mechanical damage unless <br /> .protected by approved barriers. M303.4:of the F.B.0 <br /> 12. Water.heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade, M 13:08.1 <br /> 14. Return air in all bedrooms. F.B.C. MJ 620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16: All glazing requirements are to be in accordance with R308.4-of the F.B.C. <br /> 17. All means of egress are to.be in accordance with R3 l 1 of the F.B.C. <br /> 18. "Green gypsum board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms:will be required in new construction that uses fossil=burning heating <br /> or appliances or an attached garage: They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical,.and electrical shall be separate from unit to:unit. This includes all <br /> underground plumbing and electric: <br /> 22. All 2016 N.E.C. Codes will be enforced: <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.-E.0 <br /> 24: In accordance with the Land Development Code, lots shall be,sodded before final at least 10 <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26. A copy of the energy cacls shall be with permit at all times <br /> 27. Copy of final insulation report shall be-:providled with permit before:rnaL <br /> 28:No fence,:pool.or screen enclosure is:issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />