Laserfiche WebLink
Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: ' ' n �S Permit#: p /c <br /> Job Information: <br /> Builder: �, ram( Community:- - C��,� Lot: <br /> Address: „��- . J .Unit: <br /> City: ;. 3 State: Florida Zip: 3J <br /> Air Leakage Test°Results: Passing results must meet either the Performance,Prescriptive,orERl.Method' .• `>> <br /> ® PRESCRIPTIVE'METHOD-The building ordwellingunitshallbetestedandverified-as having an air leakagerateof not excee ding 7 air changes <br /> per hour at a pressure of 0.2 inch w.g.(50.pascals)in Climate Zones 1 and 2. <br /> ❑ PERFORMANCE or ERI METHOD-The-building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the <br /> selected ACH(50)value,asshown'onFORMR405-20J7(Performance)orR406-2017(ERI),section labeled as in filtration-sub-sectionACH:,'`, t <br /> ,L7ACH(50)specified on Form R405-2o17-Ener Calc(Performance)or R406-2017(ERI): <br /> Method for calculating building volume,,,; <br /> X 60 q ® Retrieved from architectural plans e <br /> CFM50 Building Volume ACH" <br /> ❑ Code software calculated <br /> PASS E1-'• =FAIL <br /> j ❑ When ACH50 is less than.3-ACHso,.Mechanical Ventilation Field measured;and calculated ❑ Field measured'and,calculated_ <br /> r installation,•must be verified'by building department. <br /> Testing.Testing shall be conducied in accordance with ANSI/RESN ET/ICC380 and reported at'a pressure or0.2 inches w.g;(50 Pascals).Testing shall.be conducted by either <br /> 1 individuals as defined in Section 553.993(5)or(7),Florida statues,or Individuals licensed asset forth in Section <br /> 48§.105(3)(1),(g),o r(i)or an approved third party.A written report of the resu Its ofthe tests hall be signed'by.the party conclucti n'g the test and provided to the code offici.i. i . <br /> Testing shall be performed atanytime after creation ofalI pen etrationsof the buildingtiiermofe_nvelope' <br /> During testing: <br /> 'R I'Exterior windows and doors,fireplace and stove doors shall be closed,butnotsealed,beyond the intended weather-strippingor other infiltration control measures., <br /> 2 Dampers including exhaust,intake,makeup air,backdraftand fluedampers shall be closed,butnotsealed beyond intended infiltration control measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4:Exterior doors for continuous ventilation systems and heatrecoveryventilators shall be closed and sealed. ` <br /> 5.Heating and cooling systems,if installed atthe time of the test,shall be turned off. <br /> 6.Suppl 'and return registers,if installed at the time of the test,shall be fully open. <br /> Testing Company <br /> Company Name: airEnalasys Phone: 877-437=7728 <br /> rr <br /> I hereby verify that the above Air Leakage results are in accordance with the 2017 6th.Edition Florida Building Code Energy <br /> Conservation•requirements according <br /> /to the compliarice-method selected above-. ` <br /> Signature of Tester: w• Aar. Date of Test: <br /> Printed Name of Tester: William Mago <br /> License/Certification# RESNET 4309320- ..-- _Issuing Authority: .__--FSEC <br /> ---- - <br />