Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: �� Z ,� ,'l�S Permit#: p <br /> Job Information: <br /> Builder: Jj erg�;,� �;�. Community: Y COc�dL Lot: <br /> Address: -?U ✓:�,� Unit:.. _ <br /> City: ;. State: ' Florida • Zip: <br /> Air Leakage Test Results: Passing results most meet either the Performance,Prescriptive,orER1 Method , <br /> ® PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified.as having an air leakage rate of not exceeding 7•air changes <br /> per hour at a pressure of 0.2 inch w,g:(50 pascals)in Climate Zones land 2. <br /> ❑ PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the <br /> selected ACH(50)value,as shown on FORM R405-20J 7(Performance)or R406-2017(ERI),section labeled as infiltration, sub-sectionACH. <br /> 0ACH(50)specified on Form R405-2017-Ever Calc(Performance)or R406-2017(ERI): <br /> Method for calculating building volume', <br /> X 60 go'�z _ ® Retrieved from architectural plans <br /> CFM5o Building Volume ACHSO <br /> ❑ Code software calculated <br /> PASS ❑- FAIL <br /> '❑ When ACHso is less,than 3,ACHso, Mechanical Ventilation'Field measured,'and calculated ❑ Field measured'and calculated <br /> iristallation,.must be verified by building department. <br /> Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC380 and reported at a!pressure or0.2 inches w.g.(50 Pascals).Testing sh'all,be conducted by either <br /> individuals as defined In Section 553.993(5)or(7),Florida Statues,or Individuals licensed asset forth in Section <br /> 489.105(3)(1),(g),or(i)or an approved third party.Awritten report of the results ofthe testshalI be signed by.the party conducting the test and-provided to the code official. <br /> Testingshall be performed atanytimeaftercreation of all penetrations ofthebuildingthermol envelope: <br /> During testing: r, <br /> 1 Ezteriorwindows and doors,fireplace and stove doors shall beclosed,butnotsealed,beyond the intended weather-strippingorother infiltration control measures. <br /> 2 Dampers including exhaust,intake,makeup air,back draft and flue dampers shall beclosed,butnot sealed beyond intended infiltration control measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4:.Exterior doors forcontinuous ventilation systems and heatrecoveryventilators shall be closed and sealed. <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. <br /> 6.Suppl and return registers,if installed at the time of the test,shall be fully open. <br /> Testing Company <br /> Company Name: airEnalasys Phone: 877-437-7728 <br /> I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy- <br /> Conservation requirements according <br /> /to the compliance method selected above. <br /> Signature ofTester: Date of Test: 7 `,I /` <br /> Printed Name of Tester: William Mago <br /> Lice nse/Certification# RESNET4309320-. Issuing Authority: . - FSEC <br /> I <br />