Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: Ci ,��5 Permit#: ,' ' <br /> Job Information: <br /> Builder:S0111,41 <br /> Gl Community: Lot: <br /> Address: e�; ��"c/.z Unitc <br /> City: z� State: Florida Zip: <br /> Air Leakage Test Results: Passing results mustmeeteither the Performance,Prescriptive,or ER/Method <br /> ® PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding'7 air changes <br /> per hour at pressure of 0.2 inch w:g..(50.pascals)in Climate Zones 1 and 2. <br /> ❑ PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an'air leakage rate of not exceeding the <br /> selected ACH(50)value,asshown on FORM R405-20J 7(Performance)or R406-2017(ERI),section labeled as Infiltration,sub- -section ACH. <br /> . i <br /> F ,L7ACH(50)specified on Form R405-2017-Ever Calc(Performance)or R406-2017(ERI): <br /> 3 Method for calculating building volume's <br /> /. C., <br /> = l <br /> �c• X 60 ���� 7 cS � ® Retrieved from architectural plans <br /> CFM50 Building Volume ACHso ; <br /> ❑ Code software calculated <br /> ©� -PASS 0 FAIL <br /> When ACHso is less than 3 ACHso,.Mechanical Ventilation."Field measured;and calculated ❑ Field measured'and calculated <br /> imtallation•fnust 6e verhfied'by building department. <br /> Testing.Testing shall be conducted i n accordance with ANSI/RESNET/ICC380 and reported ata pressure or0.2 inches w.g:(50 Pascals).Testing shall be conducted by either <br /> '? individuals as defined lnSection 553.993(5)or(7),Florida Statues,or Individuals licensed asset forth in Section <br /> 489.105(3)(I),(g),or(i)or an approved third party.A written report of the results of the iestshall be signed by the party conducting the testand provided tothecodeofficial. <br /> Testingshallbe performed atanytimeaftercreationofallpenetrationsofthebuildingthermnienvelope` ,. <br /> During testing: <br /> 1 Exteriorwindows anddoors,fireplace andstove doorsshall beclosed,butnotsealed,beyond the intended weather-strippingor other infiltration control measures. <br /> `,2 Dampers including exhaust,intake,makeup air,back draftand flue dampers shall be closed,but notsealed beyond intended infiltration control measures. <br /> 3 Interior doors,if installed at the time of the test,shall beopen. <br /> 4:Exterior doors for continuous'ventilation systems and heat recovery ventilators shall beclosed andsealed. <br /> 5.Heating and cooling systems,if installed atthe time of the test,shall be turned off. <br /> 6.supply and return registers,if installed at the time of the test,shall be fully open. <br /> Testi'ng'Company <br /> Company Name: aiffnalasys Phone: 877-437-7728 <br /> I hereby verify_ that the above Air Leakage results are in accordance with the 2017 6th,Edition Florida Building Code Energy. <br /> Conservation requirements according <br /> /to the compliance method selected above.-=- <br /> Signature ofTesterc Date of Test: c <br /> Printed Name of Tester: "-.William Mago <br /> Lice nse/Certifi cation# RESNET 4309320'. ` Issuing Authority: _ =FSEC <br />