Laserfiche WebLink
Project Summary Job: 3246A sf ADS Carrier <br /> J Date: 9/1812018 <br /> lower floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Notes: <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 32 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 38 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 23703 Btuh Structure 18091 Btuh <br /> Ducts 2029 Btuh Ducts 2068 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 25732 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 20159 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 1332 Btuh <br /> Ducts 416 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1880 1880 Equipment latent load 1748 Btuh <br /> Volume(ft') 16486 16486 <br /> Air changes/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 21907 Btuh <br /> Equiv.AVF(cfm) 70 36 Req. total capacity at 0.85 SHR 2.0 ton <br /> Heating Equipment Summary I Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil F134CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 47'F Latent cooling 3600 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.031 cfm/Btuh Air flow factor 0.040 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O j <br /> Space thermostat Load sensible heat ratio 0.92 <br /> Capacity balance point= 35 OF <br /> Backup: <br /> Input= 7 kW, Output= 24093 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -tW- wrightsoft- 2018-Sep-18 07:14:10 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Pagel <br /> ACCK ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW <br />