Laserfiche WebLink
Single Family Dwelling <br /> Plan Review.Comments <br /> 1. F.F.E. shall be a minimum of8" above-the road elevation and an engineered site plan. <br /> 2. Lots shall be:graded to comply with R401.3 of the F.B.C: <br /> 3. Compaction test required if-24 or more of fill;dirt is brought in at any one place. <br /> 4, Tie in survey required before pouring.concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4.sides of driveway thru-the sidewalk shall-have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All.property.markers shall be uncovered and marked at time of first inspection. <br /> 8. All.A.D.A. requirements shall be met. <br /> 9. No electric,plumbing, mechanical; or framing shall be covered without an inspection and <br /> approval first: . <br /> 10. All:Garages.shall comply with section R302.6 of the F.B.C.-(Fire-Separation). <br /> I L Appliances shall not be installed in a location where subject to mechanical damage:unless <br /> protected by approved barriers. M303.4.of the F.B.0 <br /> 12. Water:heaters shall comply with section.P607.3 of the F.B.C. <br /> 13. Foundation supports_for A/C units shall be raised at least 3" above finished grade. M13.08.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be 'installed in accordance with R313.1 ofahe F.B.C. <br /> 16. All glazing requirements are to be'in accordance with R308:4.of the E.B.C. <br /> 17. All means-of egress are to be' in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702.4:2 F.B.C. <br /> 19. Combination-t <br /> . . <br /> ype AFCI breakers are.required at all locations requiring.an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil=burning heating. <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C.- <br /> 21.All plumbing,mechanical, and electrical shall be-separate from unit to:unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.Q. Codes will be enforced. <br /> 23. Tahiper= Resistant Receptacles' in accordance with 406.11;of the 2016 N.E:C <br /> 24. In accordance with.the Land Development Code, Lois shall be sodded before final.at least 10. j <br /> feet around the structure: <br /> 25. Blower door test shall be provided before.C.O. <br /> 26.. A cony of the energy cads shall be with permit at all times <br /> 27. Cbi of rind[insulation report shall be.:Provided with:Permit before:rinaL <br /> 28:No fence;.poo[or screen enclosure is issued with-this permik <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code Oh Edition <br /> R.O:W. .-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />