Laserfiche WebLink
I <br /> Building Analysis Job: 3246B sf ADS CarrierVWI <br /> g Y Date: 1/1512019 <br /> lower floor By: Dave Aldrich ! <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Tampa Intl AP, FL, US Indoor temperature(OF) 70 75 <br /> Elevation: 10 ft Design TD (OF) 38 16 <br /> Latitude: 28°N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9 <br /> Dry bulb(OF) 32 91 Infiltration: <br /> Daily range(OF) - 14 ( L ) Method Simplified <br /> Wet bulb(OF) - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> Component Btuh/ft2 Btuh % of load <br /> Walls 4.6 10317 39.7 Ducts <br /> Glazing 18.9 2976 11.4 nfiltration <br /> Doors 19.1 702 2.7 <br /> Ceilings 1.3 1524 5.9 wall <br /> Floors 3.1 5885 22.6 <br /> Infiltration 1.7 2587 9.9 <br /> Ducts 2025 7.8 Floors <br /> Piping 0 0 <br /> Humidification 0 0 <br /> Ventilation 0- 0 Glazing Do°Ceilings <br /> Adjustments 0 <br /> Total 26017 100.0 <br /> Component Btuh/ftz Btuh % of load <br /> Walls 2.4 5342 27.1 Internal Gains <br /> Glazing 44.4 7014 35.6 Wall <br /> Doors 15.6 573 2.9 Ducts <br /> Ceilings 1.8 2190 11.1 <br /> Floors 0 0 0 Infiltration <br /> Infiltration 0.4 582 3.0 j <br /> Ducts 2069 10.5 <br /> Ventilation 0 0 Ceilings <br /> Internal gains 1930 9.8 <br /> Blower 0 0 Doors <br /> Adjustments 0 <br /> Total 19700 100.0 Glazing <br /> ! <br /> Latent Cooling Load= 1801 Btuh <br /> Overall U-value= 0.102 Btuh/ftz-OF <br /> Data entries checked. <br /> wrightsoft- 2019-Jan-15 12:47:04 <br /> ^�*-• w - ^�� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ...nt\3246 at ADS vw template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW <br />