Laserfiche WebLink
i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum of.8" above the-road elevation and an engineered site plan. <br /> I Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test_required if 24" or more of fill dirt is brought in at any one place. <br /> 4, Tie in survey required before pouring.concrete. <br /> 5. Driveways require a.R.O,.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7.. All.property markers shall be uncovered and marked at time of first inspectio_n. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No:electric, plumbing,mechanical, or framing shall b,e covered without an.inspection-and <br /> approval first. <br /> 10. All.Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage finless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.R.Q. <br /> 11 Foundation supports-for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return-air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with.R313..1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means:of egress are to be m accordance with R3 l l of the F.B.C. <br /> - 18. "Green gypsum board"shall not be used 'ass-a backer.in.showers ortubs. R702.4:2:F.B,C. <br /> 19. Combination-type AFCI breakers are required of all locations requiring an AFCI.typ:e breaker: . <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil=burning heating. <br /> or appliances or an attached garage. They shall-be installed in accordance with the F.H.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to:unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br /> 23. Taiiiper=Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 . <br /> 24. In accordance with the' Land Development Code, lots shall be sodded before final at-least 10 <br /> feet around the structure: <br /> 25. Blower door test shall be provided before C.O. <br /> 26.. A cony of the energy edels shall be with permit at all times. <br /> 27. Coyy of rndl insulation report shall beyrovided with:permit before. ina� <br /> 28:No fence,.pool:or screen enclosure is:issued with this permit <br /> F.F.E.-Finished Floor Elevation . <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />