Laserfiche WebLink
I <br /> Project Summary Job: 3246E sf ADS CaTervW <br /> J ry Date: 1/15/2019 <br /> upper floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> I <br /> For: Lennar Homes <br /> Notes: Vinyl windows <br /> Design In • • <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 32 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 38 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 11113 Btuh Structure 15984 Btuh <br /> Ducts 1740 Btuh Ducts 1787 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12853 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 17771 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 3199 Btuh <br /> Ducts 361 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Coolingg (none) <br /> Area(ft') 1375 1375 Equipment latent load 3559 Btuh <br /> Volume(ft') 10998 10998 <br /> Air changes/hour 0.29 0.15 Equipment Total Load (Sen+Lat) 21330 Btuh <br /> Equiv.AVF(cfm) 52 27 Req. total capacity at 0.85 SHR 1.7 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 470F Latent cooling 3600 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.062 cfm/Btuh Air flow factor 0.045 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.83 <br /> Capacity balance point= 17 OF <br /> Backup: <br /> Input=4 kW, Output= 13485 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 1 -F�11- wrightsoft 2019-Jan-15 12:47:04 <br /> _tt_ ­­­ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> ACC ...nt\3246 sf ADS VW template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW <br />