Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road'elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R40.1.3 of the F.B.C. <br /> 3. Compaction test required:if 24"or more of fill dirt is brought in at any one place. <br /> 4, Tie in survey required before pouring.concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All.property markers shall be uncovered and marked at time of first inspectio_n. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C.-(Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage uriless <br /> protected by approved barriers. M303.4:of the F.B.0 <br /> 12. Water.heaters shall comply with section P607,3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 13.08.1 <br /> 14. Return air in all bedrooms. F.B.C. MJ620.4 <br /> 15. Smoke detectors are' o be <br /> installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308:4.of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall riot be- used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are Irequired at all.locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil.=burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2616 N.E.-C. Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24: In accordance with the Land Development Code, lots shall_ be sodded before final at least 10 <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26.. A_copy of the enerzy cacls shall be with permit at all times. <br /> 27. Copy of final insulation-report shall be.:proWded with.permit before.finab <br /> 28: No fence, pool or screen_enclosure is:issued with-this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 b Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />