Laserfiche WebLink
Buildin Anal SIS Job: 2485B sf ADS Carrier VW <br /> g Y Date: 1/15/2019 <br /> Entire House By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> i <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Tampa Intl AP, FL, US Indoor temperature(°F) 70 75 <br /> Elevation: 10 ft Design TD (°F) 38 16 <br /> Latitude: 280N Relative humidity(%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9 <br /> Dry bulb(°F) 32 91 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb(°F) - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces, 0 <br /> Component Btuh/ftZ Btuh % of load <br /> Walls 4.8 10056 31.2 Dui <br /> Glazing 19.7 4846 15.0 Wall <br /> Doors 19.0 721 2.2 nfilVat on <br /> Ceilings 1.2 2963 9.2 <br /> Floors 2.7 6616 20.5 <br /> Infiltration 2.1 3498 10.9 <br /> Ducts 3517 10.9 Floors <br /> Piping 0 0 <br /> Humidification 0 0 Glazing <br /> Ventilation 0 0 Doors Ceilings <br /> Adjustments 0 <br /> Total 32218 100.0 <br /> i <br /> Component Btuh/ftZ Btuh % of load <br /> Walls 2.5 5135 18.2 Walls Internal Gains <br /> Glazing 41.5 10218 36.2 <br /> Doors 15.5 589 2.1 <br /> Ceilings 1.7 4257 15.1 Ducts <br /> Floors 0 0 0 <br /> Infiltration 0.5 757 2.7 <br /> Ducts 3519 12.5 Infiltration <br /> 0 <br /> Ventilation 0 0 <br /> Internal gains 3750 13.3 <br /> Blower 0 0 Glazing Ceilings <br /> Adjustments 0 Doors j <br /> Total 28224 100.0 <br /> Latent Cooling Load= 3267 Btuh <br /> Overall U-value= 0.092 Btuh/ftZ-°F <br /> i <br /> Data entries checked. <br /> wr1ohtsoft- 2019-Jan-15 12:54:17 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ..ipment%2485 sf ADS VW template 3ton Canier.rup Calc=MJ8 Front Door faces:SW <br />