Laserfiche WebLink
Job: 2485B sf ADS Carrier VW <br /> Manual S Compliance Report Date: 1/1512019 <br /> Entire House By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 28224 Btuh Entering coil DB: 75.5°F <br /> Outdoor design WB: 77.2°F Latent gain: 3267 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 31491 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29750 Btuh 105% of load <br /> Latent capacity: 5250 Btuh 161% of load <br /> Total capacity: 35000 Btuh 111% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 32.1 OF Heat loss: 32218 Btuh Entering coil DB:- 69.7°F <br /> Indoor design DB: 70.0°F <br /> i, <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Output capacity: 27314 Btuh 85% of load Capacity balance: 32 OF <br /> Supplemental heat required: 4904 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 OF <br /> Meets all requirements of ACCA Manual S. <br /> -F- wrightsoft- 2019-Jan-15 12:54:18 <br /> �_ •w•���o•�-� -, Right-Suite®Universal 2018 18.0.16 RSU05714 <br /> �CA Page 1 <br /> ...ipment\2485 sf ADS VW template 3ton Carrier.rup Cale=MJ8 Front Door faces:SW <br />