My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20744
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20744
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:58:34 AM
Creation date
1/14/2020 8:58:33 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-20744
Building Department - Name
LENNAR HOMES LLC
Address
35941 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2485B sf ADS Carrier VW Builder Name: Lennar Homes 0520 <br /> Street: 35941 Saddle Palm Way Permit office: City of ephyrhills <br /> City,State,Zip: ,FL, Permit Number: •2.,a-74 <br /> Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County: .Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1720.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1408.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 312.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2443.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2443.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2443 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(207.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 390 <br /> a. U-Factor: Dbl,U=0.33 135.25 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50 <br /> c. U-Factor: Dbl,U=0.33 32.00 ft2 <br /> SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.016 ft. <br /> Area Weighted Average SHGC: 0.244 14.Hot water systems <br /> 8. Floor Types (2443.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2443.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.085 Total Proposed Modified Loads: 68.64 PASS <br /> Total Baseline Loads: 69.68 <br /> I hereby certify that the plans and specifications covered by Review of the plans and .grA <br /> this calculation are in compliance with the Florida Energy specifications covered b this r <br /> P 9Y P Y <br /> Code. calculation indicates compliance '��/} ''' _'�•�, s+ <br /> Dave <br /> lol�tGl� with the Florida Energy Code. ` iini •� ;+.0. <br /> PREPARED BY: Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed, is in com 'once Florida Statutes. __ <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OFFJAIAL <br /> DATE: DATE: <br /> - Compliance requires certification by t air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. <br /> 1/15/2019 12:55 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.