Laserfiche WebLink
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000367 3225.5 177.07 333.01 .339 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/ None HSPF:8.5 17.7 kBtu/hr 1 sys#1 <br /> 2 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 2 sys#2 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 1 sys#1 <br /> 2 Central Unit/ Split SEER: 15 28.4 kBtu/hr 852 cfm 0.85 2 sys#2 <br /> HOT WATER SYSTEM <br /> # System Type SubType Location EF Cap Use SetPnt Conservation <br /> 1 Electric None Garage 0.95 40 gal 80 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None ft2 <br /> DUCTS <br /> / —Supply— —Return— Air CFM 25 CFM25 HVAC# <br /> V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> 1 1 st Floor 6 271.6 ft 1st Floor 67.9 ft2 Proposed Qn 1st Floor —cfm 81.5 cfm 0.06 0.50 1 1 <br /> 2 Attic 6 399.2 ft 2nd Floor 99.8 ft2 Proposed Qn 2nd Floor —cfm 119.8 cfm 0.06 0.50 2 2 <br /> TEMPERATURES <br /> Programable Thermostat:Y Ceiling Fans: <br /> Coolin Jan Feb [ Mar A r [ j <br /> Ma rl <br /> Jun rl <br /> Jul X Au ri <br /> Se Oct Nov Dec <br /> Heating Jan Feb [ ]Mar f APr [ May Jun Jul AuSep Oct XNov X Dec <br /> Ventin Jan Feb X Mar [X A r [ May Jun Jul [ Aug Se [X Oct X Nov [ Dec <br /> I <br /> I <br /> 1/1 5/201 9 12:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 5 <br />