Laserfiche WebLink
Project Summary Job: 3341A sf ADS CarrierVW <br /> J ry Date: 1/1512019 <br /> lower floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Notes: Vinyl windows <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 32 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 38 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 18464 Btuh Structure 13009 Btuh <br /> Ducts 1515 Btuh Ducts 1581 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 19979 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 14590 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 936 Btuh <br /> Ducts 324 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1358 1358 Equipment latent load 1260 Btuh <br /> Volume(ft') 12105 12105 <br /> Air changes/hour 0.19 0.10 Equipment Total Load (Sen+Lat) 15851 Btuh <br /> Equiv.AVF (cfm) 38 20 Req. total capacity at 0.85 SHR 1.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING <br /> Model 25HBC518A00300 Cond 25HBC518A00300 <br /> AHRI ref 9154643 Coil FB4CNP025L <br /> AHRI ref 9154643 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER <br /> Heating input Sensible cooling 15300 Btuh <br /> Heating output 17700 Btuh @ 47'F Latent cooling 2700 Btuh <br /> Temperature rise 27 OF Total cooling 18000 Btuh <br /> Actual air flow 600 cfm Actual air flow 600 cfm <br /> Air flow factor 0.030 cfm/Btuh Air flow factor 0.041 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.92 <br /> Capacity balance point= 36 OF <br /> Backup: <br /> Input= 5 kW, Output= 18553 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -Fp- wrightsoft- 2019-Jan-15 12:39:14 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> 'CC` ...3341 sf ADS VW template 1.5-2.5tons Carrierrup Calc=MJ8 Front Door faces:SW <br />