Laserfiche WebLink
Manual S Compliance Report Job: 3341Asf ADS Carrier VW <br /> Date: 1/1 51201 9 <br /> lower floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 14590 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.2°F Latent gain: 1260 Btuh Entering coil WB: 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 15851 Btuh <br /> Indoor RH: 50% Estimated airflow: 600 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Sensible capacity: 15300 Btuh 105% of load <br /> Latent capacity: 2700 Btuh 214% of load <br /> Total capacity: 18000 Btuh 114% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 32.1 OF Heat loss: 19979 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Output capacity: 17700 Btuh 89% of load Capacity balance: 36 OF <br /> Supplemental heat required: 2279 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 600 cfm <br /> Output capacity: 5.4 kW 93% of load Temp. rise: 50 OF <br /> Meets all requirements of ACCA Manual S. <br /> 1 Wrightsoft` 2019-Jan-1512:39:14 <br /> •r•�re- uowM ,�N, Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ...3341 sf ADS VW template 1.5-2.5tons Carrier.rup Cale=MJ8 Front Door faces:SW <br />