My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20746
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20746
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:59:57 AM
Creation date
1/14/2020 8:59:55 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-20746
Building Department - Name
LENNAR HOMES LLC
Address
3305 KRESTERBROOK LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION i <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1791A1 sf ADS Carrier VW Builder Name: Lennar Homes 0130i <br /> Street: 3305 Kresterbrooke Lane Permit Office: City of 7�ephyrhills <br /> City,State,Zip: ,FL, Permit Number:Z� <br /> Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1241.30 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1817.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ftZ <br /> 6. Conditioned floor area above grade(ftZ) 1817 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl, U=0.33 87.00 ftZ <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl, U=0.58 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 <br /> I <br /> c. U-Factor: Dbl, U=0.33 23.00 ftZ <br /> SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 28.2 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.248 14.Hot water systems <br /> 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 56.95 PASS <br /> Total Baseline Loads: 58.15 <br /> I hereby certify that the plans and specifications covered by Review of the plans and :Sx4 <br /> r � .,.. <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> n with the Florida Energy Code. + <br /> PREPARED BY: Before construction is completed r . <br /> DATE: this building will be inspected for (�F 7--+ <br /> compliance with Section 553.908 <br /> I herebycertify that this building,as n is Florida Statutes. <br /> fY g g d6i 2819mpliance <br /> with the Florida Energy Code. alj' <br /> OWNER/AGENT: JAN BUILDING OFFICIAL: <br /> DATE: DATE: <br /> i <br /> - Compliance requires certification b e air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accords a with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSIIRESNET/ICC 380, is not greater than 0.030 Gin for whole house. <br /> 1/8/2019 6:52 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.