Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8 above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of All dirt is brought in at any one place_. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.M. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All.property markers shall be uncovered and marked at time of first inspection. f <br /> .8:. All A.D.A. requirements shall be met. <br /> 9. No electric,plumbing, mechanical, or framing shall be covered without an,inspection and <br /> approval first.. <br /> 10. All Garages.shall comply with section R302,6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> piotected by approved barriers. M303.4:of the F.B.0 <br /> 12. Wate'r-heaieis shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A!C units shall be raised at least 3" above finished grade. M 13.08.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16:'All glazing requirements are to be in accordance with R..308.4 of the F.B.C. !: <br /> 17. All means of egress are to be in accordance with R311 of the RB.C. <br /> 18. "Green gypsum board"shall riot be used:as a backer in showers or tubs. R702.4.2.F.B,C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI'type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> .or appliances or an attached garage.. They shall be.installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical'shall be separate from unit to:unit. This includes all <br /> undergrot nd plumbing and electric. <br /> 22. All 2016 N.E.Q. Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles m accordance with 406.11 of the 2016 N.E:C <br /> 24: In accordance with.the Land Development Code, lots shall_be.sodded before final at least 10 <br /> feet around the structure. <br /> 25.Blower door test shin be provided before C:O. <br /> 26..A copy of the energ�r eacls shall lie with permit at all times. <br /> 27. Cony of rndl insulation report shall be.=provided with:permit before.rnaL <br /> 28:No fence,:pool.or screen-enclosure is:issued with this'permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6"'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />