Laserfiche WebLink
i <br /> Job: 1941A1 sf ADS Carriervw' <br /> Manual S Compliance Report <br /> Date: 1/111 512 0 1 9 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project I • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 26071 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 4280 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 30351 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29750 Btuh 114% of load <br /> Latent capacity: 5250 Btuh 123% of load <br /> Total capacity: 35000 Btuh 115% of load SHR: 85% <br /> Heating Equipment <br /> i <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 27396 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Output capacity: 26710 Btuh 97%'of load Capacity balance: 27 °F <br /> Supplemental heat required: 686 Btuh Economic balance: -99 °F <br /> i <br /> I <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual S. <br /> t Wrightsofta 2019-Jan-15 09:46:57 <br /> �, •rrt•H he,w•w-,� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ...ipment\1941 sf ADS template VW 3ton Cartrer.rup Calc=MJ8 Front Door faces: E <br />