Laserfiche WebLink
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> ve Ornt Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 <br /> 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 <br /> 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0 <br /> 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 <br /> 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 <br /> 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0 <br /> 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 <br /> 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 <br /> 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0 <br /> 10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 <br /> 11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 <br /> 12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 <br /> 13 N=>NE Garage Frame-Wood o wic 11 12 0 8 0 96.0 ft2 0 0.23 0.01 0 <br /> 14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 <br /> 15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 <br /> _16 N=>NE Garage Frame-Wood laundry rm 11 7 5 8 0 59.3 ft2 0 0.23 0.01 0 <br /> 17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 <br /> 18 W=>NW Garage Frame-Wood foyer 11 16 4 9 4 152.4 ft2 0 0.23 0.01 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2 <br /> 2 N=>NE Insulated foyer None .2 3 6 8 20 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation => changed to Worst Case. <br /> Wall Overhang <br /> # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 S=>SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None i <br /> 2 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 3 S=>SW 5 Metal Low-E Double Yes 0.58 0.32: N 33.3 ft2 2 ft 0 in 0 ft 6 in None None <br /> 4 E=>SE 7 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 5 E=>SE 8 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 6 N=>NE 10 Vinyl Low-E Double Yes 0.33 0.21 N 23.0 ft2 1 ft 0 in 4 ft 2 in None None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 416ft2 416ft2 43.7ft 8ft 1 <br /> I <br /> 1/15/2019 9:53 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 6 ! <br />