FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> CEILING j <br /> # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type <br /> 1 Under Attic(Vented) 2nd Floor 30 Blown 1489 ft2 0.11 Wood <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ornt To 1810 Type <br /> 1 N=>NE Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 <br /> 2 E=>SE Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0 <br /> 3 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 <br /> 4 W=>NW Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0 <br /> _5 N=>NE Garage Frame-Wood 1st Floor 11 20 8 8 173.3 ft2 0.23 0.01 0 <br /> _ 6 W=>NW Garage Frame-Wood 1st Floor 11 20 8 8 8 179.1 ft2 0.23 0.01 0 <br /> _ 7 N=>NE Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0.23 0.600000 0 <br /> i <br /> _ 8 E=>SE Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0.23 0.6 0 <br /> 9 S=>SW Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0.23 0.600000 0 <br /> 10 W=>NW Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0.23 0.600000 0 <br /> 11 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Insulated 1st Floor None .2 3 6 8 20 ft2 <br /> 2 N=>NE Wood 1st Floor None .4 2 8 6 8 17.8 ft2 <br /> I <br /> WINDOWS <br /> Orientation shown is the entered orientation => changed to Worst Case. <br /> / Wall Overhang <br /> # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 3 S=>SW 11 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 4 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None <br /> 5 N=>NE 7 Vinyl Low-E Double Yes 0.33 0.21 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 6 S=>SW 9 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 7 W=>NW 10 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 8 N=>NE 7 Vinyl Low-E Double Yes 0.33 0.21 N 32.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 9 S=>SW 3 Vinyl Law-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None <br /> 10 N=>NE 1 Vinyl Law-E Double Yes 0.33 0.21 N 23.0 ft2 1 ft 0 in 1 ft 4 in Drapestblinds None <br /> I <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 427 ft2 427 ft2 41 ft 8.6 ft 1 <br /> 1/15/2019 10:21 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5 <br />