Laserfiche WebLink
i. <br /> Single Family Dwelling <br /> g Y g <br /> Plan Review Comments <br /> 1. F.F.E..shall be a minim uni of 8" above.the' road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C: <br /> 3. Compaction:test required if 24" or more of fill dirt-is brought in at any one-place_. <br /> 4, Tie in' survey required before pouring concrete. <br /> 5. Driveways require a R.O.M. use permit. All 4.sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks_shall be met. <br /> 7. All-property markers shall be uncovered and marked at time'-of first inspection. <br /> 8. All A.D.A:requirements shall be met. <br /> 9. No,electric,plumbing,mechanical, or framing shall be covered without an:inspection and <br /> approval first: <br /> 10. All Garages:shall,comply with,section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected byapproved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the,F.B.C. <br /> fAshallbraisdatles3" above finished grade, M1308.113. Foundatio' supports o a . <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> . 16.. All glazing requirements-are to be-in accordance with R.308.4.'of the F.B.C. <br /> 17. All means of egress are to.be in accordance with R311 of the RB.C. <br /> 18: "Green gypsum board" shall riot be used:' a backe'r.iri:showers or tubs, R702.4:2:F.B.C. <br /> 19.'Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> .20.- Carbon monoxide alarms will be required in new construction that uses fossil;burning heating <br /> or appliances or an attached garage: They shall-be.installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to:unit. This includes all. <br /> underground plumbing and electric. <br /> 22. All 2016 N:E.C. Codes will.be enforced: <br /> 23. Tamper=Resistant Receptacles in accordance with 406.11 of the 2016 NX-C . <br /> 24..In-accordance with.the Land Development.Code, lots shall be sodded before final.at least 10 . <br /> feet around the structure_ <br /> 25.Blower door test shall be:provided before.C.O. <br /> 26..A copy of the energy ea Is shall be with permit at all times <br /> 27..-Copy.of final in sulation'report shall be.:arovided with:permit before:fnab <br /> 28.No fence,:pool or sereenjenclosure -&&sued with this permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />