Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Cali 1828 Elev C Builder Name: DR Horton Express <br /> Street:6,835 W al ov\-Vrc,,i � Permit Office: <br /> City,State,Zip: Zephyrhills,FL, Permit Number: <br /> Owner: SV Jurisdiction: <br /> Design Location: FL,Tampa -7 10, County: Pasco(Florida Climate Zone 2 <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 <br /> b.Frame-Wood,Adjacent R=1 1.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1828.0 scift.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1828.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1828 b.N/A R. ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: NIA ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-*Factor: NIA ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sqft,) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.22 PASS <br /> Total Baseline Loads: 61.29 <br /> I hereby certify that the plans and specifications covered by Review of the plans and $!! <br /> 0 ' <br /> this calculation are in compliance with the Florida Energy specifications covered by this 0- <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: L 166 Before construction is completed <br /> DATE: 11-7-IS this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy ode.OWNER/AGENT:. BUILDING OFFICIAL: <br /> DATE: DATE: <br /> --rTri If h 7n <br /> - Compliance requires certification by the air handler unit manufacturer that the air handle enclosure qualities as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested In accordance with ANSI/RESNET/ICC 380,Is not greater than 0.060 On for whole house. <br /> 1 lt7/2018 11:31 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4 <br />