My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20785
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20785
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 9:31:43 AM
Creation date
1/14/2020 9:31:41 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-20785
Building Department - Name
DR HORTON INC
Address
6835 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> ^ <br /> ' <br /> . . <br /> Florida Building Code, Energy Conservation, 6th Edition (2017) <br /> Mandatory Requirements for Residential Performance, Prescriptive d ERI Methods <br /> F7DRESS: Permit Number: <br /> Zephyrhills,FL, <br /> MANDATORY REQUIREMENTS Sea individual Code sections for full details. <br /> V SECTION R401 GENERAL ^ <br /> �lR401.3 Energy Performance Lowe (EPud (Mandatory). The buildinguffioial shall require that an energy performance level(EPU <br /> udisplay card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law <br /> (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold arid <br /> nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components <br /> installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans <br /> and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. <br /> �l R402.4 Air leakage(Mandatory). The building thermal envelope shall ba constructed uu limit air leakage in accordance With the requirements of <br /> 8ectionvR4uu.4.1 U/mu8hR4Vc.4.n. <br /> Exception: Dwelling units of R-2 Occupancies and multiple attached single,family dwellings shall be permitted to <br /> comply with Section Q*Oz.s. <br /> �l R«ux.4'1 Building thermal enve{u-pbe building thermal envelope shall comply with Sections R*02.4.1J and R*Uz.4.1.o. <br /> -- The sealing methods between dissimilar materials shall allow for differential expansion and contraction. <br /> �l R402.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall bo installed inaccordance <br /> with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required <br /> by the code official,an approved third party shall inspect all components and verify compliance. <br /> Fl R402.4'1'2Testiog' The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air <br /> changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in <br /> accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either <br /> individuals ao defined io Section 5so. (7).Florida Statutes,or individuals licensed as set forth in Section (�,(g)or(I)or <br /> an approved third party.x written report of the results of the test shall bo signed by the party conducting the test and provided u,the code <br /> official.Testing shall bo performed au any time after creation of all penetrations nf the building thermal envelope. <br /> Exception: Testing is not required for additions,alteoationa,renovations,or repairs,of the building thermal envelope of existing <br /> buildings in which the new construction is less than 85 percent of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or <br /> other infiltration control measures. <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended <br /> infiltration control measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed, <br /> 5.Heating and cooling systems,if installed at the time of the test,shall bu turned off, <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> �l R402.4.2Rnep|unua. New wood-burning fireplaces shall have tight-fitting flue dampers o,doors,and outdoor combustion air.Where <br /> using tight-fitting doors nep|onno listed and labeled in anvnndonoo with UL 127,the dumn shall be tested and listed for the <br /> fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. <br /> �l R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per <br /> square foot(1.sUo/mx).and swinging doors no more than n.5cfm per square foot<onUshn according tuNFRC4uoor <br /> AAMA/WDMA/CSA 1 Ol/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. <br /> Exception: Site-built windows,skylights and doors. <br />
The URL can be used to link to this page
Your browser does not support the video tag.