My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20785
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20785
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 9:31:43 AM
Creation date
1/14/2020 9:31:41 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-20785
Building Department - Name
DR HORTON INC
Address
6835 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERi_Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: Permit#: <br /> Job.iMnforriiation�. •. ,, ,' .. � - .. .. . <br /> Builder: DR Horton Express Community: Lot: 7/12 <br /> Address: <br /> City: Zephyrhiils State: FL Zip: <br /> Atr i:eakage Test;Results t assrngAresults riiusf meetieifher.tlie Perfor"finance,fto grrpfrv_e;°or ERl;Mefhod ^ <br /> • i <br /> PRESCRIPTIVE NfETHOD=The'building iir dwelling unit shallibe;fested and venfied.as having;an air leakage rate of_not+exceer3ing 7sii <br /> phange"siPe�!hour at aipressure+of 0:2 inch w.g;((50 Pascals)fill Climate Zones 1 and.2. <br /> i — ;PERFORMANCE or:ERI:METHOD=The:buiidin tl or iiwellin�uni4 shall lie,te"sled and verified as-haviri",an.air leaka eirafe,of-n6t exceeding <br /> ithe,selected' AGFI_(50)value,,"as shaven:on Form'R4d5=20 7((t?eiformance}ofTi406 20.'1V(ER sect<on:labe i;!su&se8tion AGH50.z <br /> jACN(50)specified on_Form R40520y7:Energy Calc(Performance)or R406-2017(ERf): I 7.000 <br /> x 60 -- 15849 = Method for calculating building volume: <br /> CFM(50) Building Volume ACH(50) <br /> Retrieved from architectural plans <br /> DPASS 0 Code software calculated <br /> When ACH(50)is less than 3,Mechanical Ventilation installation O Field measured and calculated <br /> must be verified by building department. <br /> R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) <br /> Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section <br /> 489.105(3)(%(g),or(1)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration <br /> control measures. <br /> 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> Ttesting;Company . <br /> Company Name: Phone: ; <br /> I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code <br /> Energy Conservation requirements according to the compliance method selected above. <br /> Signature of Tester: Date of Test: <br /> Printed Name of Tester: <br /> License/Certification#: Issuing Authority: <br /> 11/7/2018 11:31:57 AM EnergyGaugeO USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.