Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E..shall be a minimum of 8 above the road elevation and an engineered.site plan. <br /> 2. Lots shall be graded to comply with R40.1.3 of the RB.C. <br /> 3. Compaction-test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use ' All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All.property markers shall be.uncovered and marked at time of.first inspection. <br /> 8. All.A.D.A:requirements shall be met. <br /> 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11,Appliances shall not be installed in a location where subject to mechanical damage:unless <br /> protected by approved barriers. M303.4:of the F.B.0 <br /> 12. Water,heateis shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation' supports for A/C units shall be raised at leastY' above finished grade. M13.08.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke deteefors'are to be 'installed in accordance with R313.1 of.the:F.B.C. <br /> 16. All glazing requirements are.to be in accordance with R308.4_of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. . <br /> 18: "Green gypsum board" shall not be used as a backer.in showers or tubs.R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker: <br /> 20.. Carbon monoxide alarms:will be required in new construction that uses fossil:burning heating <br /> or appliances or an attached garage: They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C- Codes will be enforced. <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N:E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure: <br /> 25. Blower'doortest shall be provided before:C:O. <br /> 26..A cove of the energy cads shall be Edith permit at all times. <br /> 27. Copy offindl insulation report shall be.:proWded with:permit before rinab <br /> 28: No fence, pool or screen enclosure is.issued with this Pernik. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6`h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />