Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be.graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if.24" or more of fill dirt is brought in at any,one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require'a R.-O.W. use permit. A11.4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met: <br /> 7. All.property markers shall be uncovered and marked at time'of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric, plumbing,mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All.Garages shall comply with section R302.6 of the F.B.C..(Fire separation). <br /> 11._Appliances.shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4.of the F.$:C <br /> 12. Water.heaters shall comply with section.P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M13.08.1 <br /> -14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be'installed in accordance with R313.1 of.the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All 'means of egress are to.be in accordance with R3l l of the F.B.C. <br /> 18. "Green gypsum board"shall riot be used as a backer iri.'show ers or tubs. R702.4.2.F.B.C. <br /> 19. Combination-type AFCI breakers are required at all..locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new.construction that uses fossil-burning heating <br /> or appliances'or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit.to.unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. In accordance with.the Land Development.Code, lots shall be sodded before final.at least 10. <br /> feet around the structure: <br /> 25. Blower door test shall be.provided before CO. <br /> 26.. A cove of the energy earls shall be with Hermit at all times <br /> 27. Copy:of eindl insulation report shall be.:provided with:permit before:final <br /> 28: No fence;:pool or screen enclosure is:issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A:-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />