My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20814
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20814
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 9:45:24 AM
Creation date
1/14/2020 9:45:23 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR RIDGE
Building Department - Doc Type
Permit
Permit #
19-20814
Building Department - Name
DUGAN,WILLIAM & MOLLY
Address
6112 RIDGEWAY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I , <br /> e. <br /> GENERAL NOTES: <br /> 1. THIS STRUCTURE WAS DESIGNED IN ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE WITH STATE AMENDMENTS,(2015 IBC). <br /> 2. ALL MATERIALS AND LABOR SHALL BE IN ACCORDANCE WITH THE ABOVE CODE AND ALL OTHER APPLICABLE LOCAL CODES AT THE TIME OF MANUFACTURE. <br /> 3. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. <br /> 4. THE FOUNDATION PLAN IS A SEPARATE SET OF PLANS FOR APPROVAL BY LOCAL MUNICIPALITIES. <br /> 5. EXTERIOR DIMENSIONS CAN VARY BETWEEN LIMITS SHOWN AT 2'O.C.BUT MEMBER SPACING SHALL NOT EXCEED LIMITS AS INDICATED. <br /> 6. ALL THE FOLLOWING LUMBER SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA USE CATEGORY UC4B(GROUND CONTACT,HEAVY DUTY)-SKIDS. <br /> 7. ALL THE FOLLOWING LUMBER SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA USE CATEGORY UC3B(EXTERIOR ABOVE GROUND,UNCOATED OR POOR WATER <br /> RUNOFF)-FLOOR JOISTS,PLYWOOD FLOOR DECKING,AND EXTERIOR RATED WOOD STRUCTURAL PANEL SIDING. <br /> / 8. ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED(G185)OR STAINLESS STEEL. <br /> F 9. ALL WINDOWS WITHIN 24"OF DOORS,AND ALL GLASS IN DOORS SHALL BE SAFETY,TEMPERED,OR ACRYLIC PLASTIC SHEET. <br /> 10. FOR ROOFS WITH ASPHALT SHINGLES AND A SLOPE BETWEEN 2 TO 12 AND 4 TO 12 SHALL HAVE A DOUBLE UNDERLAYMENT APPLICATION AS REQUIRED IN ACCORDANCE WITH <br /> SECTION 1507.2.2 OF THE 2015 IBC OR PER SHINGLE MANUFACTURER INSTRUCTIONS. z <br /> w <br /> 11. UNDERLAYMENT SHALL CONFORM WITH SECTION 1507.2.3 OF THE 2015 IBC OR PER SHINGLE MANUFACTURER INSTRUCTIONS. <br /> 12. ASPHALT SHINGLES SHALL CONFORM WITH SECTION 1507.2.5 OF THE 2015 IBC ATTACHMENT OF ASPHALT SHINGLES SHALL CONFORM WITH 1507.2.7 OF THE 2015 IBC. w <br /> 13. FASTENERS FOR ASPHALT SHINGLES SHALL CONFORM TO SECTION 1507.2.6 OF THE 2015 IBC. 2 <br /> 14. TIE-DOWNS SHALL MEET THE REQUIREMENTS OF ALL APPLICABLE CODES. <br /> 15. THESE PLANS HAVE NOT BEEN DESIGNED FOR HVHZ REQUIREMENTS AS SET FORTH IN THE 2015 IBC OR FOR USE AS A COMMERCIAL BUILDING. wa <br /> j 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS: r <br /> 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY AND PLACEMENT OF LAWN STORAGE UNIT TO ENSURE THE INTEGRITY OF THE BUILDING AND ITS COMPONENT PARTS. x <br /> 18. NO FIELD REVISIONS TO ANY STRUCTURAL COMPONENTS OR DEVIATIONS FROM THESE DRAWINGS SHALL BE MADE. -- <br /> 19. THE OWNER AND THE CONTRACTOR SHALL HOLD HARMLESS THE ENGINEER FROM AND AGAINST ALL LIABILITY CLAIMS,DAMAGES,LOSSES AND EXPENSES INCLUDING LEGAL FEES W <br /> - ARISING OUT OF OR RESULTING,FROM ERRORS OR OMISSIONS IN THE PERFORMANCE OF THE WORK BY THE CONTRACTOR. _ <br /> 20. SECTIONS AND DETAILS ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY AT ALL SIMILAR LOCATIONS,UNLESS OTHER SECTIONS AND DETAILS ARE ,. <br /> ' SPECIFICALLY REFERENCED. _ <br /> 21. REFER TO SUPPLIED FASTENING SCHEDULE FOR FASTENING BASED ON CONNECTION AND LOCATION OF MEMBERS AS PER 2015 IBC TABLE 2304.10.1 UNLESS NOTED OTHERWISE. ........... <br /> 22. BUILDINGS HAVE BEEN DESIGNED FOR LP SMARTSIDE STRAND SUBSTRATE PANEL SIDING,LP SMARTSIDE PRECISION LAP SIDING SHALL BE USED WITH'XSTRAPS OR .r vG,EMS* j <br /> STRUCTURAL Z' y m <br /> SHEATHING AS DETAILED IN THIS PLAN SET W0.23437 Z <br /> 23. FASTENERS IN LP SMARTSIDE STRAND SUBSTRATE PANEL SIDING MUST NOT BE INSTALLED IN PANEL SIDING GROOVES IN THE FIELD OF THE PANEL SIDING OR WHEN THE PANEL P I " <br /> SIDING GROOVES OCCUR AT CUT EDGES OF THE PANEL SIDING. 1 1s. I h a a <br /> 24. REFER TO THE ICC-ES EVALUATION REPORT ESR-1301/3090 FOR ADDITIONAL DATA AND SPECIFICATIONS OF LP SMARTSIDE STRAND SUBSTRATE PANEL/LAP SIDING. �Q)NIF_ - . w <br /> 25. MAX OPENINGS WIDTHS MUST COMPLY WITH DESIGN RATIOS AS PER ANSI/AF&PA SDPWS-2015.BUILDINGS HAVE BEEN DESIGNED TO HAVE ONLY OPENINGS WITH MAX WIDTHS ��,� G. �� w <br /> 4Ftir e�,. Z <br /> EQUAL TO THOSE IN THE ENDWALL SHEAR WALL CHART. lllnllu,,,,, <br /> 26. PER SECTION 1609.1.2 OF THE 2015 IBC,STORAGE SHEDS THAT ARE NOT DESIGNED FOR HUMAN HABITATION AND THAT HAVE A FLOOR AREA OF 720 SQUARE FEET OR LESS ARE <br /> NOT REQUIRED TO COMPLY WITH THE MANDATORY WIND-BORNE-DEBRIS-IMPACT STANDARDS OF THE 2015 IBC. `O R G 'o <br /> 27. BUILDINGS HAVE BEEN DESIGNED TO HAVE ANCHORS DIRECTLY ATTACHED TO ALL FOUR CORNERS OF THE BUILDING TO RESIST TENSION FORCES FROM LATERAL WIND LOADS. w <br /> THIS DESIGN CONSIDERATION MUST BE MADE BY INSTALLER WHEN ATTACHING ANCHORING SYSTEM TO BUILDING. C�J�,�41S1 ERFO <br /> 28. UNLESS NOTED OTHERWISE,ATTACH ALL MANUFACTURED PRODUCTS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. PE029466 ~ <br /> 29. 2X4 SP#2 PRESSURE TREATED LUMBER SHALL BE SUBSTITUTED FOR 2X4 SPF#2 LUMBER IN WALLS FOR USE IN FLOOD PLAINS. * PR FES,;AoNAL <br /> 30. PER APA PRODUCT REPORT PR-N124,LP SMARTSIDE STRAND SUBSTRATE SERIES TREATED-ENGINEERED-WOOD PANEL AND LAP SIDING IS PERMITTED ON WALLS FOR USE IN z FLOOD PLAINS. \ �WGIhE�R' �i z 31. 19/32"LP PROSTRUCT FLOORING WITH SMARTFINISH IS PERMITTED IN LIEU OF 5/8"APA RATED STRUCTURAL SHEATHING ON FLOOR.INSTALL PER MANUFACTURER INSTRUCTIONS. \G <br /> FN7 M•� $ <br /> U <br /> yJ.�N caRo4,,,, o <br /> O.eQocessi ., Z <br /> 1583If T. o <br /> t ,� ri <br /> ill IAiA z <br /> a <br /> 07/13/18 w <br /> 1552 6TH ST..WINTER HAVEN,FL 33880 H <br /> (863)865-6502 <br /> ::j <br /> GENERAL NOTES <br /> DATE: 07113/18 DRAWN BY: RD <br /> SCALE:AS NOTED CHECKED BY: KMBfRSHEEr20Fl5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.