Residential Pools- <br /> E4203.1 Receptacle outlets. <br /> Receptacles outlets shall be installed and located in accordance with Sections.E4203..1.1 .through. <br /> E4203.1.5: Distances shall be measured as the,shortest.path that an appliance supply cord connected <br /> to the:receptacle would follow without penetrating a floor, wall, ceiling, doorway with hinged or sliding <br /> door,window opening,'or other effective permanent barrier. [680.22(A)(5)] <br /> E4203.1.2Where required. <br /> At least one 125:-volt, 15-or 20.=ampere receptacle supplied by a general-purpose branch circuit shall <br /> be' located a.miriimum of 6 feet 1829 mm from and not.more than 20 feet 6096 nim .:from theJnside <br /> wall of pools and outdoor spas and hot tubs. This, receptacle shall be.located not more than 6 feet;:6 <br /> inches (1981 mm) above the floor, .platform or grade level serving the pool, spa or hot -tub. <br /> [680.22(A)(1)] <br /> R4501.17Residential'swim nil ng barrier requirement. <br /> Residential swimming.pools shall comply with Sections R4,501.17.1 through R450.1.17.3. . <br /> Exception: A swimming pool with an approved safety pool cover complying with.ASTM F134.6. <br /> 11450147.1Outdoor swimming pools. <br /> Outdoor swimming pools shall be provided with a barrier complying with R4501.17.1.1 through <br /> R4501 A-1.1.14. <br /> R450.1.17.1-1 <br /> The top.of the barrier shall be.at least 48 inches (1219 mm) above grade measured on the side of <br /> the.barrier which faces away from the swimming pool. The maximum vertical clearance between <br /> grade and the bottom of the barrier shall be 2 inches (51 mm).measured on the side of the barrier <br /> which faces away from the swimming pool. Where the top of the pool structure is.above grade the <br /> barrier may be at. ground level or mounted on top of the pool structure. Where the barrier is <br /> mounted on top:of the pool structure, the-maximum vertical clearance between the top of the pool <br /> structure and the bottom of the barrier shall be 4:inches (102 MM'): <br /> R4501.17.1.2 <br /> The barrier may not have.any gaps, openings;indentations, protrusions, or structural components <br /> that could allow a young child to crawl under, squeeze through;.or climb.over the barrier as herein <br /> described.below. One end of a removable child barrier shall not be removable without the aid.of' <br /> tools: Openings in any barrier shall not allow passage of'a 44iichi.diameter.(102 mm) sphere. <br /> R4501:17.1.3 <br /> Solid barriers which do not have openings shall not contain indentations or protrusions except for <br /> normal construction tolerances and tooled masonry-joints., <br /> R450.1.17-1.4 <br /> Where the barrier is composed of horizontal and-vertical members and the distance between.the <br /> tops of.the horizontal members is less than 45 inches (1143 mm),the.horizontal members shall be <br /> located on the swimming pool side of the fence. Spacing between vertical members shall not <br /> exceed 11,inches (44 mm) in width:Where there are decorative cutouts within veftical members, <br /> spacing within the cutouts.shall not exceed 1 inches.(44 mm) in width: <br /> R4501.17.1:5 <br /> Where the barrier is composed of hori2ontal and vertical members and the distance between the <br /> tops of the horizontal members is 45 inches(1143 mm)or more;spacing between vertical members <br />