GENERALNOTES WINFORCE HORIZONTAL SLIDER WINDOW <br /> 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK <br /> EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMANVDMA/CSA NON-IMPACT <br /> 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA APPROVED CONFIGURATIONS <br /> BUILDING CODE,6TH EDITION(2017). CONFIGURATIONS NOTED AS HVHZ DESIGN <br /> APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE ACCEPTABLE REQUIRED HVHZ IMPACT <br /> FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. CONFIGURATION GLAZING' APPROVED PRESSURE RATING <br /> 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT RATING <br /> PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 74"x63"XX 2SL TYPE A YES +50/-50 PSF <br /> 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING AREAS LIMITED 84"x66"XX 2SL TYPE B YES +50/-50 PSF <br /> BY ASTM E-1300 GLASS TABLES,AND TESTED WATER AND STRUCTURAL 104"x66"XOX EQUAL LITE TYPE A YES +50/-50 PSF <br /> PRESSURES. <br /> 4.THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE THE 93"x66"XOX 1/4-1/2-1/4 TYPE ASASH YES +55/-55PSF NONE <br /> INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE TYPE B FIXED <br /> CONFIGURATIONS SHOWN IN THE ELEVATIONS. 'X'INDICATES OPERABLE 104"x66"XX 2SL TYPE B NO +40/40 PSF <br /> PANEL,'O'INDICATES FIXED PANEL. INSTALL PRODUCTS WITH MAXIMUM <br /> SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT,AND WITH <br /> FASTENER TYPE AS SHOWN IN THE DETAILS AND AS INDICATED IN TABLE 1. 104"x66"XOX 1/4-1/2-1/4 TYPE B NO +40/-40 PSF <br /> FOR FULL PRODUCT CONSTRUCTION DETAILS SEE NCTL TEST REPORTS <br /> 210-4067-01/01A/01B/01C,AND 210-4081-01B/01C/02B/03B/04A/04C 'SEE GLAZING DETAILS,SHEET 2 <br /> 5.APPROVED MINIMUM GLAZING IS AS SHOWN IN GLAZING DETAILS ON <br /> SHEET 2 AND AS SPECIFIED IN ALLOWABLE CONFIGURATIONS TABLE ON INSTALLATION 74"MAX.WINDOW WIDTH <br /> THIS SHEET. FASTENER 6"MAX. <br /> 10-1/2"MAX. <br /> 6.THE 413 ALLOWABLE STRESS INCREASE FACTOR(SHORT-TERM INCREASE LOCATION,TYP. ON CENTER, FROM <br /> FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS FOR THIS � CORNER, <br /> SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF ANCHORAGE NP TYP. <br /> INTO WOOD SUBSTRATE. <br /> 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS)AND <br /> ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND SHALL 32-5/8"MAX. _ <br /> BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR AS DLO,TYP. C9 <br /> APPROVED BY THE AUTHORITY HAVING JURISDICTION(AHJ). BUCKING, }a} w <br /> OPENINGS,&BUCKING FASTENERS MUST BE PROPERLY DESIGNED& 0~ v = LUCKS <br /> INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO TRANSFER u;of X _ X 3 Turner <br /> SUPERIMPOSED LOADS TO THE STRUCTURE. WITH MASONRY OPENINGS, z p 2018-03-13 <br /> WOOD BUCKS ARE OPTIONAL. :E O ;'-! z 21:43+20:00 <br /> 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE COATED <br /> OR OTHERWISE PROTECTED TO PREVENT GALVANIC REACTIONS. WOOD U <br /> IL <br /> BUCKS,IF USED,SHALL BE PRESSURE TREATED,WITH EITHER W <br /> TREATMENT OR COATING COMPATIBLE WITH THIS PRODUCT. U F- �`5•.�c£ s..L��.,,� <br /> 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING z SILL ANCHOR SPACING <br /> � Ito 5e2atT :�s <br /> COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL OTHER SAME AS HEAD <br /> WINDOW MATERIALS. 74"x63"XX 2SL ELEVATION <br /> 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH THESE %o'• 'L; <br /> DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BYA FLORIDA o ai..... <br /> `�n REGISTERED PROFESSIONAL ENGINEER ON ASITE-SPECIFIC BASIS. TABLE OF CONTENTS , ,U„,A;11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER SHEET DESCRIPTION NORTHEAST BUILDING PRODUCTS <br /> INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE 1 NOTES,ELEV., 4280 Aramingo Ave.,Philadelphia,PA 19124 i� <br /> RESPONSIBILITY OF OTHERS AND ARE NOTADDRESSED BY THIS CONFIG.TABLE Ph.(215)535-7110 www.camelotwindows.com 3/12/2018 <br /> DOCUMENT. 2 ELEV.,GLAZING SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. <br /> 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 3 XOX ELEV. NOTES,ELEVATION 4/13/2017 FL PE#58201 <br /> SHEET 5. 4 VERTICAL SECT. 1239 Jabara Ave. <br /> 5 HORIZ.SECTIONS SCALE: NTS REV:B_ North Port,FL 34288 <br /> 6 BOM,PART DWGS DRAWING:FPA-WINFORCE-SL-NI SHEET: 1 OF Ph.941-380-1574 <br />