Laserfiche WebLink
ft <br /> aax ars <br /> FOR MAX. OVERALL UNIT WIDTH, SEE WINDOW FOR MAX. OVERALL UNIT WIDTH, SEE WINDOWi: ac <br /> PRESSURE TABLE ON THIS SHEET PRESSURE TABLE ON THIS SHEET <br /> 48" MAX. INDMDUAL 48" MAX. INDIVIDUAL 48" MAX. INDIVIDUAL 48" MAX. INDIVIDUAL 48" MAX. INDIVIDUAL 48" MAX. INDIVIDUAL 3 <br /> WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH <br /> 2'TO 3' 2'TO 3' 4" 4 4" 4" 4" A2 4" 4" 4" 4" 4" <br /> -- 5 <br /> SEE SINGLE WINDOWCLUSTER FIN " FRAME SCREWS <br /> ELEVATION FOR FIN MIDDLE ANCHOR NOT _ <br /> ANCHOR ANCHORS AT MULLION WHERE SHOWN AT <br /> REQUIRED AT EACH <br /> I INDIVIDUAL WINDOW ( ENDS SUCH THAT I INDIVIDUAL WINDOW I HEAD. SEE "FRAME <br /> REQUIREMENTS & WINDOW WHEN WINDOW IS <br /> WIDTHS ARE RESTRICTED THERE ARE A TOTAL WIDTHS ARE RESTRICTED ANCHOR 43 <br /> POSITIONS AROUND 30" OR LESS WIDE. <br /> • WINDOWS TO DIMENSIONS SHOWN � OF 4 POSITIONED AS 7O DIMENSIONS SHOWN I REQUIREMENTS $ <br /> BUT OVERALL UNIT SHOWN. SEE "FRAME BUT OVERALL UNIT III TABLE"ON SHEET 1 <br /> FRAME WIDTH SHALL ANCHOR SEE SINGLE WINDOW FRAME WIDTH SHALL FOR REQUIREMENTS. <br /> CONTROL REQUIREMENTS = ELEVATION FOR ANCHOR CONTROL <br /> TABLE ON SHEET 1 w REQUIREMENTS & I I Z w N <br /> w I I FOR REQUIREMENTS. = POSITIONS AT SIDES OF o <br /> WINDOWS <br /> 00 <br /> a l <br /> S0 <br /> Z � n <br /> n � Z aN <br /> I I I I tq . <br /> J r <br /> 7 Zco <br /> • 4 4 4 N w <br /> EXTERIOR ELEVATION: <br /> MULTIPLE WINDOWS INSTALLATION CUPS WHERE SHOWN. SEE EXTERIOR ELEVATION: <br /> MIDDLE ANCHOR NOT Z.4 <br /> (FIN INSTALLED_SERtES i01 `FRAME ANCHOR REQUIREMENTS TABLE"ON MULTIPLE WINDOWS REQUIRED AT EACH w o bZ <br /> SCALE: 3/4" = 1'-0" SHEET 1 FOR REQUIREMENTS, WINDOW WHEN WINDOW EE w� � <br /> NOTE CUPS MAY BE USED AT HEAD ALSO (FRAME SCREW INSTALLED SERIES 20) w t'z - <br /> IS 30" OR LESS,WIDE. u) <br /> IN UEU OF FRAME SCREWS SCALE: 3/4" = 1'—O" P-5!2xW <br /> �N Ii— <br /> ALLOWABLE DESIGN PRESSURE (DOUBLE & TRIPLE WINDOWS) PRESSURE SHOWN IN THIS TABLE IS <br /> OVERALL ALLOWABLE FOR INSTALLATION SIGNCONDITIONSONLY. �3tQi Xi <br /> WINDOW SIZE PRESSURE THE GOVERNING DESIGN PRESSURE ON g 441 <br /> MAX. MAX MUWDN STILE FIXED SASH ACTIVE SASH (pOSffWE THE WINDOWS SHALL BE THE LESSER <br /> FRAME FRAME REINFORCEMENT REINFORCEMENI MEETING RAIL MEETING RAIL & OF THAT SHOWN IN THE INDIVIDUAL <br /> TYPE REINFORCEMENT REINFORCEMENTNEGAT WINDOW'S STATE APPROVAL OR THAT <br /> WIDTH HEIGHT ,*•. fi ,°°" .g y� <br /> QN.) (IN.) (PSF) SHOWN IN THIS TABLE. •°°uT z <br /> All <br /> DOUBLE WINDOWS <br /> 72 53.5 1 N/A ND NO YES 35 . <br /> 72 59.5 1-BAR NO NO YES 35 HIGH PERFORMANCE Zk <br /> 72 65.5 I-BAR YES YES YES 50 4� . <br /> 72 1 72 I I-BAR YES NO YES 40 WINDOW NOTE: - `� '•° E;�g;w <br /> W21 <br /> A NO YES YES 35 1. ALL WINDOWS ARE RESTRICTED BY THE DIMENSIONS SPECIFIED. 9.r°;�d�b'' e.C•,. 3 <br /> [-BAR NO YES YES 35 2. TRIPLE WINDOW SHOWN. DOUBLE WINDOW ALSO APPLIES. o� b�•°L t� ��a4a <br /> BAR YES YES YES 35 3. IF MORE THAN 3 WINDOWS ARE TO BE MULLED IN ONE OPENING, �eJ411 I;. w•WG N REV. <br /> TRIPLE WINDOWS ALLOWABLE PRESSURE ON THOSE UNITS SHALL BE AS STATED FOR THE 1572 F <br /> A No NO YES 3S COMPARABLE TRIPLE UNIT. mim a <br /> BAR NO NO YES 35 <br /> BAR YES NO YES 40 2 Gv t} <br />