My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20889
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20889
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 10:59:15 AM
Creation date
1/14/2020 10:59:13 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-20889
Building Department - Name
LENNAR HOMES LLC
Address
39631 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job: 1791A1 sf ADS Carrier VW <br /> Manual S Compliance Report Date: 11/28/2018 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Cooling-Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 22330 Btuh Entering coil DB: 75XF <br /> Outdoor design WB: 77.3°F Latent gain: 2873 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 25203 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 24140 Btuh 108% of load <br /> Latent capacity: 4260 Btuh 148% of load <br /> Total capacity: 28400 Btuh 113% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 25932 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L <br /> Actual airflow: 1000 cfm <br /> Output capacity: 22528 Btuh 87% of load Capacity balance: 30 °F <br /> Supplemental heat required: 3404 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1000 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual S. <br /> t wrightsoft` 2018-Nov-28 15:56:05 <br /> •�.���w� ,�w, Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ACCK ..ment11791 sf ADS template VW 2.5ton Carrier.rup Calc=MJ8 Front Door faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.