19-20891
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20891
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 11:00:35 AM
Creation date
1/14/2020 11:00:34 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-20891
Building Department - Name
LENNARHOMES LLC
Address
3004 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e <br /> . Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E..shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R,O.W. use permit: All 4 sides of driveway_ thru the sidewalk shall have_ <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7:. All,property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> 9; Na electric,.plumbing; mechanical, or framing shall be:covered without an inspection and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appli 'ces.shall not be installed in a location where subject to mechanical damage unless <br /> protected-by approved barriers. M303;4 of the F.B.0 <br /> 12. Waterheaters shall comply with section P607.3 of the F.B:C. <br /> 13. Foundation,supports for A/C units shall be raised at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms, F.B.C. M1620.4 <br /> 1-5. Smoke detectors are to be installed in accordance with R313.1 of the' -F.B.C. <br /> 16:All glazing requirements are to be iri.accordance with R308.4 of the F:B:C: <br /> 17. All means of egress are to be in accordance with R31 I of the F.B.C: <br /> 18. ``Green "sum' .board" shall not.be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 19: Combiriatiori-type AFCI breakers are required at all locations requirin' an AFCI type breaker. <br /> 20. Carbon monokide alarms will be'required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />