Laserfiche WebLink
E <br /> Single Family. Dwelling <br /> Plan Review Comments <br /> 1. F.F.E;.shall be a minimum of 8 above the road elevation-and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the.F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4.. Tie in survey required before,pouring concrete. <br /> 5. Driveways'require a R.O:w. use permit. All 4 sides of driveway thru the sidewalk_shall,have <br /> expansion material. <br /> .6: All setbacks shall be met. <br /> -7.- All.property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall,be met: <br /> 9: Na electric,.plumbing;mechanical, or.framing shall be covered without an:inspection and <br /> approval first: <br /> 10:.All Garages shall comply with section,-R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to'me6hanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above'finish grade. M1308:1 <br /> 14: Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16: All glazing requirements are to be in' accordance with R308.4 of the F.B.C, <br /> 17. All means,of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed-in accordance with the F.B.C: <br /> .21. All plumbing,mechanical; and electiical.shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 21 All 2016 N.E.C. Codes will be enforced. <br />